Download Print this page

Detailed Specifications - Fluke TiR32 Technical Data

Building diagnostic thermal imagers
Hide thumbs Also See for TiR32:

Advertisement

Detailed specifications

Temperature
Temperature measurement range
(not calibrated below -10 °C)
Temperature measurement
accuracy
On-screen emissivity correction
On-screen reflected background
temperature compensation
On-screen transmission correction
Imaging performance
Image capture frequency
Detector type
Thermal sensitivity (NETD)
Infrared spectral band
Visual (visible light) camera
Minimum focus distance
Standard infrared lens type
Field of view
Spatial resolution (IFOV)
Minimum focus distance
Optional telephoto infrared lens type
Field of view
Spatial resolution (IFOV)
Minimum focus distance
Optional wide-angle infrared lens type
Field of view
Spatial resolution (IFOV)
Minimum focus distance
Focus mechanism
Image presentation
Palettes
Standard
Ultra Contrast
Level and span
Fast auto toggle between manual
and auto modes
Fast auto-rescale in manual mode
Minimum span (in manual mode)
Minimum span (in auto mode)
IR-Fusion
information
®
Automatically aligned (parallax
corrected) visual and IR blending
Picture-In-Picture (PIP)
Full screen infrared
Color alarms (temperature alarms) Dewpoint temperature alarm (user-selectable)
Voice annotation
Image capture and data storage
Image capture, review, save
mechanism
Storage medium
File formats
Export file formats w/SmartView
®
software
Memory review
2 Fluke Corporation
TiR32, TiR1 and TiR Thermal Imagers
TiR32
-20 °C to +150 °C (-4 °F to +302 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Yes
9 Hz refresh rate or 60 Hz refresh rate
depending upon model variation
320 X 240 Focal Plane Array, uncooled
microbolometer
≤ 0.05 °C at 30 °C target temp. (50 mK)
Industrial performance 2.0 megapixel
1.25 mRad
11.5 ° x 8.7 °
0.63 mRad
45 cm (approx. 18 in)
46 ° x 34 °
2.50 mRad
7.5 cm (approx. 3 in)
Ironbow, Blue-Red, High Contrast,
Amber, Amber Inverted, Hot Metal,
Grayscale, Grayscale Inverted
Ironbow Ultra, Blue-Red Ultra, High Con-
trast Ultra, Amber Ultra, Amber Inverted
Ultra, Hot Metal Ultra, Grayscale Ultra,
Grayscale Inverted Ultra
Smooth auto-scaling and manual scaling of level and span
2.0 °C (3.6 °F)
3 °C (5.4 °F)
Three levels of on-screen IR blending displayed in center of LCD
Three levels of on-screen IR blending displayed on LCD
60 seconds maximum recording time per image; reviewable playback on imager
The TiR32 allows user to adjust
palette, blending, level, span, IR-Fusion
mode, emissivity, and reflected back-
ground temperature compensation, and
transmission correction on a captured
image before it is stored.
SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with
60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via
Non-radiometric (.bmp) or (.jpeg) or
fully-radiometric (.is2)
No analysis software required for
non-radiometric (.bmp and .jpeg) files
Thumbnail view navigation and
review selection
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
TiR1
-20 °C to +100 °C (-4 °F to +212 °F)
Yes
Yes
160 X 120 Focal Plane Array, uncooled microbolometer
≤ 0.07 °C at 30 °C target temp. (70 mK)
7.5 µm to 14 µm (long wave)
Industrial performance 1.3 megapixel
46 cm (approx. 18 in)
23 ° x 17 °
2.5 mRad
15 cm (approx. 6 in)
Manual, one-handed Smart Focus capability
Ironbow, Blue-Red, High Contrast,
Amber, Hot Metal, Grayscale
Yes
Yes
Yes
The TiR1 allows user to adjust palette,
®
blending, level, span, IR-Fusion
emissivity, and reflected background
temperature compensation on a captured
image before it is stored.
One-handed image capture, review, and save capability
included multi-format USB card reader
Non-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometic bitmap (.bmp) files
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Sequential image navigation and review
TiR
-20 °C to +100 °C (-4 °F to +212 °F)
± 5 °C or 5 % (at 25 °C nominal,
whichever is greater)
9 Hz refresh rate
≤ 0.1 °C at 30 °C target temp. (100 mK)
2.5 mRad
Ironbow, Blue-Red,
High Contrast, Grayscale
2.5 °C (4.5 °F)
5 °C (9 °F)
100 % IR displayed in center of LCD
100 % IR displayed on LCD
mode,
®

Advertisement

loading

This manual is also suitable for:

Tir1Tir