Figure 7-6: Measurement Condition - Fluke ThermoView TV30 Series User Manual

Thermal imager camera
Table of Contents

Advertisement

Name
Value
Operator
Output
Output Type
Output
Example

Figure 7-6: Measurement Condition

defines the name of the condition
The value can be provided from an AOI, a constant temperature value, or the internal
device temperature.
Defines the comparison operation between the value and a fixed temperature. The
logical operator is selectable between Greater Than or Less Than
Alarm: outputs a digital value 0/1 when the condition is true. The system goes into
the alarm state.
Signal: outputs a digital value 0/1 when the condition is true. The system does not
go into the alarm state.
defines the desired output channel
deletes the condition.
Condition will be become true if maximum temperature of Rect AOI is greater than
50°C then activate an alarm on the internal output 1 of the camera.