To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
4. Lift up to remove control panel assembly from two
keyhole screws.
5. Tilt control panel assembly forward and disconnect
four connectors to remove from range.
6. Remove grommets from control panel assembly.
7. Remove three screws and false drip tray handle from
control panel assembly.
8. Reverse procedure for installation.
Oven Function Selector Removal
Condition Requirements:
Control Panel Assembly Removed
1. Disconnect connector from the oven function
selector.
2. Remove two screws, bezel, and the oven function
selector from the control panel assembly.
3. Reverse procedure for installation.
©2009 Viking Preferred Service
Oven Thermostat Removal
Condition Requirements:
Control Panel Assembly Removed
1. Disconnect connector from the oven thermostat.
2. Remove two screws, bezel, and the oven thermostat
from the control panel assembly.
3. Reverse procedure for installation.
Element Selector Switch Removal
Condition Requirements:
Control Panel Assembly Removed
1. Mark and disconnect connectors from the element
selector switch.
2. Remove two screws, bezel, and the element selector
switch from the control panel assembly.
3. Reverse procedure for installation.
Disassembly