Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Convection Fan Switch Removal

Condition Requirements:
Control Components Accessed
1. Mark and disconnect connectors from convection fan
switch.
2. Press tabs on both ends of the switch and push
switch through control panel.
3. Reverse procedure for installation.

Oven Light Switch Removal

Condition Requirements:
Control Components Accessed
1. Mark and disconnect two connectors from light
switch.
2. Press tabs on both ends of the switch and push
switch through control panel.
3. Reverse procedure for installation.
26

Oven Light Bulb Removal

Condition Requirements:
Door Lowered
DO NOT touch bulb with bare hands. Clean off any
signs of oil from the bulb and handle with a soft cloth.
1. Unsnap glass light cover using a screwdriver in the
access groove.
2. Firmly grasp light bulb and pull out.
3. Replace with halogen bulb using volt and wattage
requirements listed on glass cover.
4. Replace the light cover by snapping glass cover onto
metal box.
1
3

Spark Module Removal

Condition Requirements:
Control Components Accessed
1. Disconnect connectors from module.
2. Pull to remove module from burner valve.
3. Reverse procedure for installation.