Backguard Assembly Removal - Viking VESC530 Service Manual

30 inch electric range
Hide thumbs Also See for VESC530:
Table of Contents

Advertisement

Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
3. Remove two screws and hinge receiver from range.
4. Reverse procedure for installation.

Backguard Assembly Removal

Condition Requirements:
Rear of Range Accessed
1. Remove four screws and backguard assembly from
range.
2. Place backguard assembly on suitable work surface.
3. Remove 17 screws and back.
40
4. Remove inner diverter.
5. Remove six screws, end caps, and top from front
support.
6. Remove fi ve screws and slide front support from front
panel.
Note: Pry corner of front panel slightly to allow front
support to slide from the front panel.
7. Reverse procedure for installation.