ALARM CONTROL

I System Controller Behavior
during the Alarm Mode
When an alarm signal is input to cameras or system units,
this system controller is notified that an alarm has been
activated. Then, the ALARM indicator will blink. During the
alarm mode, "Alarm" sign will blink on the LCD, and the
camera number is displayed as "- - -".
Mon01 Cam---
When an alarm is automatically canceled (=alarm auto
reset mode), "Alarm" sign changes from blinking to steady
light, and the LCD display returns to the normal status.

I Alarm Reset

You can cancel the alarm mode ("Alarm" sign is blinking.)
or alarm auto reset mode (The ALARM indicator is light-
ing.). The alarm inputs to all the system units will be reset
all together.
Press ALM RESET/ALM ALL RESET button.
The alarm mode or alarm auto reset mode of all the system
units will be cancelled, and the ALARM indicator will go out.
Notes:
• Alarm behaviors differ depending on connected system
units. Refer to the operating instructions of system units.
• You cannot cancel the alarm mode or alarm auto reset
mode of each system unit one by one.

I Alarm Suspension

You can temporarily stop alarm inputs to all the system
units in the following procedure.
1. Press the ALARM/ALM SUSPEND button while holding
down the SHIFT button.
The alarm inputs will be suspended and the ALM SUS-
PEND indicator will light up.
2. To
cancel
the
ALARM/ALM SUSPEND button again while holding
down the SHIFT button. The alarm suspension mode
will be canceled, and the ALM SUSPEND indicator will
go out.
54
HD316
Alarm
alarm
suspension
mode,
Note: You cannot suspend each alarm input one by
one. The alarm inputs to all the system units will be
suspended all together.

I Alarm History Search

To play back a desired alarm image, the alarm history table
of selected system unit can be displayed. The following
procedure is available when the selected system unit can
display the alarm history table.
Note: WJ-HD300 Series does not support alarm history
search.
G How to Display Alarm History Tables
1. Press the ALM RECALL button.
"Alarm Recall" sign will appear on the LCD, and the
alarm history table will be displayed on an active moni-
tor.
Alarm Recall
2. Perform operations while watching the active monitor.
Note: The operation details differ depending on
recorders. Refer to pp. 55 to 56.
Controls commonly available
<Main unit>
Shuttle ring clockwise:
• Moves to the next page.
• Moves the cursor. (Available for WJ-HD500 or WJ-
HD200 Series)
Shuttle ring counterclockwise:
• Moves to the previous page.
• Moves the cursor. (Available for WJ-HD500 or WJ-
HD200 Series)
JogDial clockwise or counterclockwise:
• Moves the cursor.
• Changes the selected parameter. (Available for WJ-
HD500 or WJ-HD200 Series)
+ button: Increases a numeric value.
– button: Decreases a numeric value.
Numeric buttons: Enters numeric parameters.
CAM (SET) button: Determines the selected parame-
press
ter.
MON (ESC) or EXIT button: Closes the search list dis-
play.