I Ps·data Communication Setting - Panasonic WV-CU650 Operating Instructions Manual

System controller
Hide thumbs Also See for WV-CU650:
Table of Contents

Advertisement

G Operation
1. Turn off the power.
Note: If you set the MODE Switch #1 to #4 to ON, you
can skip entering the administrator password in
Step 3.
2. Turn on the power while holding down the buttons 2, 4,
and 6.
"Admin Password" will appear on the LCD to enter the
password.
All Reset
Admin Password _____
3. Enter the administrator password.
The password entered will be displayed as "∗" marks.
All Reset
Admin Password ∗ ∗ ∗ ∗ ∗
Notes:
• The factory default is "650".
• To delete a character, press the CLEAR button.
• If you have entered a wrong password, the LCD
display will return to Step 2.
4. Press the CAM (SET) button.
If the password entered is correct, all the settings will
be reset to the factory default.
All Reset
All Reset
5. Check "End" on the LCD.
Check "End" has appeared on the LCD to inform you of
the initialization end.
All Reset
6. Turn off the power.
End
I PS·Data Communication Setting
This setting is required to establish a connection between
the system units and system controller.
List of PS·Data communication settings
Setting Item Available setting parameter(s)
Baud Rate 4800 / 9600 / 19200 bps
Data Bit
8 bit (Fixed)
Parity Bit
None / Odd / Even
Stop Bit
1 / 2 bit
Wait Time
OFF / 100 msec / 200 msec /
400 msec / 1000 msec
Group Adr A to Z
Xon/Xoff
Not Use (Fixed)
Note: Factory defaults are underlined.
G Operation
1. Turn off the power.
2. Turn on the power while holding down the button 6 and
MON (ESC) button.
"Admin Password" will appear on the LCD to enter the
password.
PS Data Com. Setup
Admin Password _____
3. Enter the administrator password.
The password entered will be displayed as "∗" marks.
PS Data Com. Setup
Admin Password ∗ ∗ ∗ ∗ ∗
Notes:
• The factory default is "650".
• To delete a character, press the CLEAR button.
4. Press the CAM (SET) button.
If the password entered is correct, "Baud Rate" setting
form will appear on the LCD.
PS Data Com. Setup
Baud Rate
Notes:
• If the password entered is wrong, "PS·Data Com.
Setup" will appear on the LCD again to reenter the
password.
• You can change the setting item display on the LCD
by rotating the JogDial.
9600