Gate3[I].Chan[0].Compa (Pwm Output Setting - Omron CK3M Seres Hardware User Manual

Programmable multi-axis controller
Table of Contents

Advertisement

Bit
Name
31 to 13 Status
12
Status Parity Stores the parity bits added to the status data.
11 to 00 Reserve
For CK3W-GC2£00 Units (SL2-100)
Depending on the channel, this setting varies as follows.
Register
Gate3[i].Chan[0].SerialEncDataB X-axis status
Gate3[i].Chan[1].SerialEncDataB Y-axis status
Gate3[i].Chan[2].SerialEncDataB Z-axis status
Note Gate3[i].Chan[3].SerialEncDataB is not used.
Bit
Name
31
TxRx_Error
30
Power_OK
29
Temp_OK
28
Position_Ack
27
Data for mainte-
nance
26 to
Reserve
14
13 to
Data for mainte-
8
nance
7 to 0
Number of
frames received
*1.
Depending on the timing of starting communications with the Galvo Scanner, TxRx_Error may turn ON in
the detection of the first frame.
Do not use a user program to check the error that may occur at the start of communications.
A-9-6

Gate3[i].Chan[0].CompA (PWM Output Setting)

Description PWM output setting
CK3M/CK5M Series Programmable Multi-Axis Controller Hardware User's Manual (O036)
Stores the status data sent from the Galvo Scanner.
For details on the status data, refer to the manual for the Galvo Scanner.
Use a user program to check that the parity is correct.
Always set 0.
Description
Detects an error in communications with the Galvo Scanner.
0: Communications normal
1: Communications abnormal
Shows the status of the internal power supply voltage of the Galvo Scanner.
0: Internal power supply voltage abnormal in the Galvo Scanner
1: Internal power supply voltage normal in the Galvo Scanner
If any internal power supply voltage error is found, follow the manual for the Galvo
Scanner to remove it.
Shows the status of the internal temperature of the Galvo Scanner.
0: Internal temperature abnormal in the Galvo Scanner
1: Internal temperature normal in the Galvo Scanner
If any internal temperature error is found, follow the manual for the Galvo Scanner
to remove it.
Shows that the Galvo Scanner received position data.
0: The Galvo Scanner did not receive position data.
1: The Galvo Scanner received position data.
Used for maintenance.
Always set 0.
Used for maintenance.
Counts the number of frames received by the CK3W-GC Unit.
Since a frame comes every 10 µs, you can confirm that the reception data is com-
ing when you check that this data is counting up.
Function
Function
*1
Appendices
A
A-37