Option 64: No Arm on Panel Low Battery

(Default = off)
Determines whether the system prevents users from arming if a
low CPU battery trouble condition exists (on) or not (off).
To turn on No Arm on Panel Low Battery, press:
Add—Option #—64—DONE.
To turn off No Arm on Panel Low Battery, press:
Delete—Option #—64—DONE.
Option 65: No Usage Report (Default = off)
Determines whether the panel sends a No Usage report to the
central station if the user has not operated the system before the
programmed time expires (on) or not (off). The timer starts
each time the system is disarmed.
This is a customer service feature that alerts the central station
if a customer is not using their security system. The service
provider can then contact the customer to find out why the sys-
tem is not being used, and help correct any problems for the
customer.
The time can be set from 001 to 254 days. Entries must be 3
digits.
To turn on No Usage Report, press:
Add—Option #—65—001 - 254—DONE.
To turn off No Usage Report, press:
Delete—Option #—65—DONE.
Option 66: External Siren Delay (Default = off)
Determines whether external siren activation is delayed 30 sec-
onds after an alarm activation (on), or if external siren activa-
tion is immediate upon alarm activation (off).
To turn on External Siren Delay, press:
Add—Option #—66—DONE.
To turn off External Siren Delay, press:
Delete—Option #—66—DONE.
Option 67: Quick Exit (Default = off)
Determines whether pressing the disarm button when the sys-
tem is armed activates the exit delay time to allow exit and re-
entry without disarming the system (on) or not (off).
This feature is useful if the user wants to step outside briefly
and return, such as to get the paper. If the system is armed and
the user presses the Disarm button, the panel announces "Exit
time on" and sounds exit delay beeps. This allows a designated
entry/exit door to be open for up to 2 minutes without causing
an alarm. When the door is closed, the beeps stop and the door
is armed again.
Note
For UL listed systems, Quick Exit must be off.
24
Beta Test 8/10/01
To turn on Quick Exit, press:
Add—Option #—67—DONE.
To turn off Quick Exit, press:
Delete—Option #—67—DONE.
Option 68: Swinger Shutdown (Default = on)
Determines whether the panel prevents the same sensor from
activating an alarm more than once in a single arming period
(on) or not (off).
Note
Swinger Shutdown does not affect smoke and fire sen-
sors.
To turn on Swinger Shutdown, press:
Add—Option #—68—DONE.
To turn off Swinger Shutdown, press:
Delete—Option #—68—DONE.
Option 69: SIA Limits (Default = on)
Determines whether Entry, Exit, and Dialer delay times fall
within SIA limits (on) or factory ranges (off).
The following table shows the available settings when this
option is on or off.
Affected
Option
Option 10:
Entry Delay
Option: 11
Exit Delay
Option: 17
Dialer Delay
To turn on SIA Limits, press:
Add—Option #—69—DONE.
To turn off SIA Limits, press:
Delete—Option #—69—DONE.
SIA Limits
SIA Limits
Factory Ranges
(Option 69 on)
(Option 69 off)
030-254 seconds
005-254 seconds
045-254 seconds
005-254 seconds
015-045 seconds
005-045 seconds