Testing the System

This section describes how to perform the following test proce-
dures:

Control Panel

Testing sensors

Testing phone communication
Testing central station communications
Testing the X-10 Lamp Modules
You should test the system after installing, after servicing, and
after adding or removing devices from the system.
Control Panel
Test the Control Panel by pressing the buttons as described
below.
ARM Doors & Windows-The panel arms Doors & Win-
dows. Press twice to eliminate the programmed entry
delay. The button will blink when No Entry Delay is on.
ARM Motion Sensors-The panel will arm Motion Sen-
sors. Press twice to turn Latchkey on. The button blinks
when Latchkey is on.
DISARM -The panel will prompt you to enter an access
code. Enter the appropriate code and the panel will disarm
Doors, Windows, and Motion Sensors.
Arming Levels
Arming Level
0
Bypasses 24 hour intrusion sensors
(Master Access Code Only)
1
Disarm the system
2
Arm Doors and Windows
3
Arm Motions
4
Arm Doors, Windows, and Motions
Two beeps verify that Door/Window sensors are
armed.
One beep indicates the system is disarmed
Three beeps verify that Motion Sensors are armed.
Four beeps verify that both Door/Window and Motion
sensors are armed.
SYSTEM STATUS-Press to determine system status and
system time.
CHIME Doors-Press to enable two beeps that will sound
from the interior siren output, the panel siren, and the X-
10 powerhorn siren (if set to unit number 9) when a pro-
tected door or window learned into sensor group 10 or 13
is opened.
CHIME Special Motion- Press to enable three beeps that
will sound from the interior siren output, the panel siren,
and the X-10 powerhorn siren (if set to unit number 9)
when a Motion Sensor that is programmed as sensor type
25 is activated. If there are no sensors learned into sensor
group 25, this function will not be available. The control
panel will also announce which sensor was tripped if
chime voice (option 41) is on.
LIGHTS Time Activated-Press to enable system con-
trolled lights to turn on/off at a scheduled time.
LIGHTS Sensor Activated-Press to enable system con-
Beta Test 8/10/01
Description of Level
trolled lights to turn on for 4 minutes when a specific sen-
sor is tripped.
AUX, POLICE, FIRE-Press and hold or press twice
quickly to activate a non-medical, police, or fire emer-
gency alarm
Testing Sensors
We recommend that you test the sensors after all programming
is completed and whenever a sensor-related problem occurs.
Note
While the sensor test is a valuable installation and ser-
vice tool, it only tests sensor operation for the current
conditions. You should perform a sensor test after any
change in environment, equipment, or programming.
1.
Place all sensors in their secured (non-alarm) state.
2.
Open the panel cover.
3.
Enter the appropriate access code.
4.
Press Test.
The panel responds with Sensor test, press again to change or
DONE to select.
5.
Press DONE.
The panel will prompt you to trip each sensor one at a
time. You may follow the panel voice prompting or test
the sensors in any order. Use the "Sensor Tripping
Instructions" table on the next page to trip sensors.
Testing the System
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

60-tbd-95r

Table of Contents