Option 21: Opening Reports (Default = off)
Determines whether the panel sends opening reports to a cen-
tral station or pager whenever the system is disarmed (on), or
not (off).
To turn on Opening Reports, press:
Add—Option #—21—DONE.
To turn off Opening Reports, press:
Delete—Option #—21—DONE.
Option 22: Closing Reports (Default = off)
Determines whether the panel sends opening reports to a cen-
tral station or pager whenever the system is armed (on), or not
(off).
To turn on Closing Reports, press:
Add—Option #—22—DONE.
To turn off Closing Reports, press:
Delete—Option #—22—DONE.
Option 23: Force Armed Report (Default = off)
Determines whether the panel sends a force armed report to a
central station or pager if the user bypasses protesting sensors
(indirect bypass) when arming the system (on), or not (off).
To turn on Force Armed Report, press:
Add—Option #—23—DONE.
To turn off Force Armed Report, press:
Delete—Option #—23—DONE.
Option 24: AC Power Failure Report (Default = off)
Determines whether the panel sends AC power failure reports
to a central station or pager after the programmed time expires
(on), or not (off).
When the panel is without AC power for 30 seconds, the panel
LEDs turn off. When the panel is without AC power for the
programmed time, an AC power failure is reported. The panel
reports an AC power restoral when AC power returns to the
panel.
The time can be set from 5-254 minutes. Entries must be 3 dig-
its.
Note
For UL listed systems, AC Power Failure must be set to
15 minutes.
To turn on AC Power Failure Report, press:
Add—Option #—24—005 - 254—DONE.
To turn off AC Power Failure Report, press:
Delete—Option #—24—DONE.
Beta Test 8/10/01
Option 25: CPU Low Battery Report (Default = on)
Determines whether the panel sends a low CPU battery report
to the central station when the panel backup battery voltage
drops below 5.4 volts (on), or not (off).
To turn on CPU Low Battery Report, press:
Add—Option #—25—DONE.
To turn off CPU Low Battery Report, press:
Delete—Option #—25—DONE.
Option 26: Fail to Communicate (Default = on)
Determines whether the panel and interior sirens sound trouble
beeps if it is unable to successfully send a report to a central
station or pager (on), or not (off).
To turn on Fail to Communicate, press:
Add—Option #—26—DONE.
To turn off Fail to Communicate, press:
Delete—Option #—26—DONE.
Option 27: Ring/Hang/Ring (Default = 1)
Determines when the panel answers a remote phone access or
Toolbox call. Depending on whether an answering machine
exists at the panel location, off-site access to the panel can be
done with a series of phone calls or just one.
The following table shows the available settings.
For off-site access where an answering machine does not exist,
the user or ToolBox operator simply calls the panel location
once and listens for 10 rings. The panel should answer after the
tenth ring.
For off-site access where an answering machine exists, the user
or ToolBox operator must perform the following steps:
1.
2.
Note
For UL listed systems, CPU Low Battery Report must be
on.
Note
For UL listed systems, Fail to Communicate must be on.
Ring/Hang/Ring Settings
Setting
Control Panel answers after:
1
ring/hang/ring or 10 rings
2
ring/hang/ring/hang/ring or 10 rings
3
ring/hang/ring/hang/ring/hang/ring or 10 rings
4
10 rings
Off
Disabled—no remote (off-site) access
Call the panel location.
Let the phone ring once, then hang up.
Programming
17