Option 40: Trouble Beeps; Option 41: Chime Voice; Option 42: Speaker Level; Phone Mod 3 - Interlogix Simon 3 Installation Instructions Manual

Hide thumbs Also See for Simon 3:
Table of Contents

Advertisement

Programming
Option 40: Trouble Beeps (Default = on)
Determines whether the panel, X-10, and hardwire interior
sirens sound six beeps every minute when a trouble condition
occurs (on) or not (off). The following conditions cause trouble
beeps:
AC power failure
Low CPU battery
Sensor failure (supervisory)
Sensor trouble (low battery or tripped tamper)
Fail to communicate
No Activity timer has timed out. Trouble beeps continue
for 5 minutes and if the panel does not see activity, trouble
beeps stop and the panel reports the no activity to the cen-
tral station.
Trouble beeps can be silenced by arming or disarming the sys-
tem, or by pressing the STATUS button. Trouble beeps resume
4 hours later if the trouble condition is not cleared.
Note
For UL listed systems, Trouble Beeps must be on.
To turn on Trouble Beeps, press:
Add—Option #—40—DONE.
To turn off Trouble Beeps, press:
Delete—Option #—40—DONE.
Option 41: Chime Voice (Default = off)
Determines whether the panel voice announces the sensor
number and name (on) or not (off), when the CHIME Doors or
CHIME Special Motion features are on and sensors in groups
10, 13, and 25 are tripped while the system is disarmed.
To turn on Chime Voice, press:
Add—Option #—41—DONE.
To turn off Chime Voice, press:
Delete—Option #—41—DONE.
Option 42: Speaker Level (Default = 8)
Sets the volume of voice messages from the panel speaker.
The volume can be set from 1 (lowest) to 8 (highest). Turning
off this option returns the setting to the default value.
To set Speaker Level, press:
Add—Option #—42—1 - 8—DONE.
To turn off Speaker Level (return to default), press:
Delete—Option #—42—DONE.
Option 43: Numeric Pager/Voice Event Notification
Phone Number (Default = off)
Lets you program up to a 26-digit phone number for numeric
pager or remote phone reporting (on), or delete an existing
phone number (off).
20
Beta Test 8/10/01
When used to call a numeric pager, a 3-digit code appears on
the pager display to identify the report. When used to call a
remote phone, a person at the remote phone location can hear
system voice alarm announcements. See the "Testing" section
for more information.
Press Test for each required pause, Add for a *, and Delete for
a # (each of which uses one of the 26 available places).
Note
Some pagers may require 3 or 4 additional pauses after
the last digit to work correctly.
To set Numeric Pager/Voice Event Notification Phone
Number, press:
Add—Option #—43—Up to 26 digits—DONE.
Note
Pressing DONE is required if you enter fewer than 26
digits. The phone number is automatically stored without
pressing DONE if all 26 places are used.
To delete Numeric Pager/Voice Event Notification Phone
Number, press:
Delete—Option #—43—DONE.
Option 44: Numeric Pager/Voice Event Notification
Determines the report content and reporting format when
Option 43: Numeric Pager/Voice Event Notification Phone
Number is programmed. The following table describes the
choices. All entries must be 2 digits.
Setting #
08
09
10
To set Numeric Pager/Voice Event Notification Phone
Mod 3, press:
Add—Option #—44—08, 09, or 10—DONE.
To reset Numeric Pager/Voice Event Notification Phone
Mod 3 (return to default), press:
Delete—Option #—44—DONE.
Phone Mod 3 (Default = 09)

Phone Mod 3

Content
Latchkey, No Activity, Phone Test,
Openings, Closings, Fail to Open/
Close, AC Power Restorals/
Failures
Same as setting 8 plus Alarms
Alarms only
Format
Numeric
Pager
Numeric
Pager
Voice Event
Notification

Advertisement

Table of Contents
loading

This manual is also suitable for:

60-tbd-95r

Table of Contents