About This Manual

This manual provides information for planning, installing, pro-
gramming, and testing this security system. When necessary,
this manual refers you to other documentation included with
compatible devices.
Planning sheets are included for you to record sensor locations
and software programming settings.

Special Installation Requirements

This security system can be used as a fire warning system, an
intrusion alarm system, an emergency notification system, or
any combination of the three.
Some installations may require configurations dictated by city/
state codes, insurance, or Underwriter's Laboratories (UL).
This section describes the various component and configura-
tion listings.

UL Listed Installations

This section describes the requirements for UL Listed installa-
tions.
Note
The control panels described are not currently UL Listed.
Basic System
Control Panel (60-TBD-95R or 60-TBD-95R)
Backup Battery 12V 1.2 AH (60-TBD)
Standard Class II 9 VAC, 700 mA Power Transformer
(22-109-ITI) or Class II 9 VAC, 700 mA Line Carrier
Power Transformer (22-TBD)
Hardwire Interior Siren (13-374) or Hardwire Exterior
Siren (13-046)
Household Burglary Alarm System Unit (UL 1023)
Basic system, plus:
Hardwire Magnetic Contact (13-068 or 13-071) or
Wireless Learn Mode Door/Window Sensor (60-362)
Option 01: Panel Piezo Beeps turned on
Option 10: Entry Delay set to 45 seconds
Option 11: Exit Delay set to 60 seconds
Option 12: Phone Mod 1 turned on
Option 16: Auto Phone Test set to 001
Option 19: RF Timeout set to 24 hours
Option 24: AC Power Failure Report turned on
Option 25: CPU Low Battery Report turned on
Option 26: Fail to Communicate turned on
Option 29: Control Panel Alarms turned on
Option 39: Siren Timeout set to 4 minutes or more
Option 40: Trouble Beeps set to on
Option 50: RF Jam Detect set to on
Option 53: Hardwire Siren Supervision turned on if
Option 29: Control Panel Alarms is turned off
Option 59: Exit Extension turned off
Option 67: Quick Exit turned off
Beta Test 8/10/01
Household Fire Warning System (UL 985)
Basic system, plus:
UL 1023 & 985 24-Hour Backup
UL 1635 Digital Alarm Communicator System

Central Station Reporting

The panel has been tested with the following central station
receivers using SIA and Contact ID reporting formats:

UL Canada Listed Installations

This section describes the requirements for CUL (UL Canada)
Listed installations.
Canadian Standards CSA Certified Accessories
Residential Burglary Alarm System Unit
(ULC-S309)
Basic system as described for "UL Listed Installations" plus:
Residential Fire Warning System Control Unit
(ULC-S545-M89)
Basic system as described for "UL Listed Installations" plus:

California State Fire Marshall Listed Installations

Applied for.
Wireless Smoke Sensor 60-506-319.5 or 60-838-95
learned into sensor group 26
Option 01: Panel Piezo Beeps turned on
Option 19: RF Timeout set to 4 hours
Option 24: AC Power Failure Report turned on
Option 29: Control Panel Alarms turned on
Option 40: Trouble Beeps set to on
Option 50: RF Jam Detect set to on
Option 53: Hardwire Siren Supervision turned on if
Option 29: Control Panel Alarms is turned off
For 24-hour backup, the total current draw for all con-
nected devices is limited to XX mA (during normal
standby conditions) using a 1.2 AH battery.
Same as UL 1023 & 985
ITI CS-5000 Central Station Receiver
Sur-Gard Central Station Receiver with models
SG-DRL2A and SG-CPM2
Hardwire Magnetic Contact (13-068 or 13-071) or Wire-
less Learn Mode Door/Window Sensor (60-362)
Wireless Smoke Sensor 60-506-319.5 or 60-838-95
learned into sensor group 26
Option 01: Panel Piezo Beeps turned on
Option 19: RF Timeout set to 4 hours
Option 40: Trouble Beeps set to on
1RWH
For 24-hour backup, external power drain is limited to
XX mA (during normal standby condition) using a 1.2
AH battery.