Option 35: Fail to Close Report (Default = off)
Determines whether the panel sends a Fail to Close report to a
central station or pager if the system has not been armed by the
programmed time (on), or not (off).
Note
System time must be set correctly for this feature to work.
To turn on Fail to Close Report, press:
Add—Option #—35—Hours—Minutes—DONE.
To turn off Fail to Close Report, press:
Delete—Option #—35—DONE.
Option 36: Sensor Activated Light Lockout Start
Time (Default = off)
Sets the START time that determines when the panel prevents
the sensor activated lights feature from turning on sensor acti-
vated lights.
Note
System time must be set correctly for this feature to work.
When a time value is set (on) and the sensor activated lights
feature is on, the panel prevents sensor activated lights from
turning on between the programmed start time (this option) and
the programmed stop time (Option 37).
Note
Both Options 36 and 37 must have a time programmed
for this feature to work correctly.
When both Options 36 and 37 are turned off and the sensor
activated lights feature is on, sensor activated lights turn on at
all times.
To set Sensor Activated Light Lockout Start Time, press:
Add—Option #—36—Hours—Minutes—DONE.
To turn off Sensor Activated Light Lockout Start Time,
press:
Delete—Option #—36—DONE.
Option 37: Sensor Activated Light Lockout Stop
Time (Default = off)
Sets the STOP time that determines when the panel prevents
the sensor activated lights feature from turning on sensor acti-
vated lights.
Note
System time must be set correctly for this feature to work.
When a time value is set (on) and the sensor activated lights
feature is on, the panel prevents sensor activated lights from
turning on between the programmed start time (Option 36) and
the programmed stop time (this option).
Note
Both Options 36 and 37 must have a time programmed
for this feature to work correctly.
When both Options 36 and 37 are turned off and the sensor
activated lights feature is on, sensor activated lights turn on at
all times.
Beta Test 8/10/01
To set Sensor Activated Light Lockout Stop Time, press:
Add—Option #—37—Hours—Minutes—DONE.
To turn off Sensor Activated Light Lockout Stop Time,
press:
Delete—Option #—37—DONE.
Option 38: Auto Arm (Default = off)
Determines how long the system protests (announces open/
failed sensors) when attempting to arm with open/failed sen-
sors, before bypassing these sensors and automatically arming
the rest of the system.
When this option is on, the panel announces all open/failed
sensors repeatedly for 4 minutes, then automatically bypasses
the open sensors and arms the rest of the system.
Pressing the ARM Doors & Windows button a second time
(before the 4-minute time expires) bypasses all open sensors
and arms the rest of the system. Pressing this button a third
time eliminates the entry delay.
To turn on Auto Arm, press:
Add—Option #—38—DONE.
When this option is off, the panel announces all open/failed
sensors once, then automatically bypasses the open sensors and
arms the rest of the system.
To turn off Auto Arm, press:
Delete—Option #—38—DONE.
Option 39: Siren Timeout (Default = 4 min.)
Determines how long sirens sound alarms if no one is present
to cancel the alarm (disarm the system).
The time can be set from 002 - 254 minutes. Entries must be 3
digits. When this feature is turned off, sirens sound alarms until
the alarm is canceled (system is disarmed).
To set Siren Timeout, press:
Add—Option #—39—002 - 254—DONE.
To turn off Siren Timeout, press:
Delete—Option #—39—DONE.
Note
The panel protests an arming attempt when it has not
received a restore (close) signal from sensors learned
into restore-specific sensor groups. Sensors learned into
group 26 (Fire) cannot be bypassed. See "Sensor Group
Characteristics" in "Appendix B" to identify sensor groups
with restore signal requirements.
Note
This option must be turned on for Option 52: Unvacated
Premises to work correctly.
Note
For UL listed systems, Siren Timeout must be set to at
least 4 minutes.