Option 01: Panel Piezo Beeps; Option 02: Panel Voice; Option 03: Latchkey; Option 04: Primary Phone Number - Interlogix Simon 3 Installation Instructions Manual

Hide thumbs Also See for Simon 3:
Table of Contents

Advertisement

Option 01: Panel Piezo Beeps (Default = On)
Determines whether the panel piezo produces beeps based on
system activity (on) or is silent (off). The following table
describes all possible beeps.
Panel Piezo Beeps
Activity
Piezo Beep Response
ARM Doors &
Exit Delay—2 beeps sound every 5
Windows
seconds and 2 times per second during
the last 10 seconds.
Silent Exit—2 beeps sound at the
beginning of the exit delay and 2 more
sound just before the exit delay expires.
Entry Delay—2 beeps sound every 5
seconds and 2 times per second during
the last 10 seconds.
ARM Motion
Exit Delay—3 beeps sound every 5
Sensors
seconds and 3 times per second during
the last 10 seconds.
Silent Exit—3 beeps sound at the
beginning of the exit delay and 3 more
sound just before the exit delay expires.
Entry Delay—3 beeps sound every 5
seconds and 3 times per second during
the last 10 seconds.
ARM Doors/
Exit Delay—4 beeps sound every 5
Windows &
seconds and 4 times per second during
Motion Sensors
the last 10 seconds.
Silent Exit—4 beeps sound at the
beginning of the exit delay and 4 more
sound just before the exit delay expires.
Entry Delay—4 beeps sound every 5
seconds and 4 times per second during
the last 10 seconds.
DISARM
1 beep
CHIME
2 beeps (when programmed)
DOORS
CHIME
3 beeps (when programmed)
SPECIAL
MOTION
Trouble Beeps
6 beeps every minute. Press SYSTEM
STATUS to stop beeps for 4 hours.
No Activity
20 beeps every minute for 5 minutes
(when programmed)
To turn on Panel Piezo Beeps, press:
Add—Option #—01—DONE.
To turn off Panel Piezo Beeps, press:
Delete—Option #—01—DONE.
Note
For all UL listed systems, Option 1 must be on (added).
Beta Test 8/10/01
Option 02: Panel Voice (Default = On)
Determines whether the panel announces all status, alarm, and
program mode messages (on), or only announces messages for
canceled alarms, open sensors (protesting), when SYSTEM
STATUS is pressed, or if the panel is in program mode (off).
To turn on Panel Voice, press:
Add—Option #—02—DONE.
To turn off Panel Voice, press:
Delete—Option #—02—DONE.
Option 03: Latchkey (Default = Off)
Determines whether the panel reports a Latchkey alarm if the
system is not disarmed at a preset time between midnight and
11:59
To set Latchkey, press:
Add—Option #—03—Hours—Minutes—DONE.
To turn off Latchkey, press:
Delete—Option #—03—DONE.
Option 04: Primary Phone Number (Default = none)
Lets you program up to a 26-digit central monitoring station
receiver phone number for monitored systems (on), or delete
an existing primary phone number (off).
Press Test for each required pause, Add for a *, and Delete for
a # (each of which uses one of the 26 available places).
To set Primary Phone Number, press:
Add—Option #—04—Up to 26 digits—DONE.
To delete Primary Phone Number, press:
Delete—Option #—04—DONE.

Option 05: Secondary Phone Number

Lets you program up to a 26-digit central monitoring station
receiver/numeric pager phone number for monitored systems
(on), or delete an existing secondary phone number (off).
Press Test for each required pause, Add for a *, and Delete for
a # (each of which uses one of the 26 available places).
.
. (on), or if the Latchkey feature is disabled (off).
P
M
Note
The system clock must be set for the Latchkey feature to
work.
Note
Pressing DONE is required if you enter fewer than 26
digits. The phone number is automatically stored without
pressing DONE if all 26 places are used.
(Default = none)
Programming
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

60-tbd-95r

Table of Contents