Option 06: Downloader Phone Number; Option 07: Account Number; Option 08: Phone Lock; Option 09: Downloader Code - Interlogix Simon 3 Installation Instructions Manual

Hide thumbs Also See for Simon 3:
Table of Contents

Advertisement

Programming
Note
For numeric pagers, add 2 pauses at the end of the num-
ber. Some pagers may require 3 or 4 additional pauses to
work correctly. Pagers that require the panel to dial more
than 26 digits will not work.
The panel calls a numeric pager twice for each report.
Silent alarms report to a pager as an intrusion alarm. See
the Table "Pager Reporting Messages" for more reporting
information.
To set Secondary Phone Number, press:
Add—Option #—05—Up to 26 digits—DONE.
Note
Pressing DONE is required if you enter fewer than 26
digits. The phone number is automatically stored without
pressing DONE if all 26 places are used.
To delete Secondary Phone Number, press:
Delete—Option #—05—DONE.

Option 06: Downloader Phone Number

(Default = none)
Lets you program up to a 26-digit phone number for a com-
puter modem for using ITI ToolBox Downloader (on), or
delete an existing phone number (off).
Press Test for each required pause, Add for a *, and Delete for
a # (each of which uses one of the 26 available places).
To set Downloader Phone Number, press:
Add—Option #—06—Up to 26 digits—DONE.
Note
Pressing DONE is required if you enter fewer than 26
digits. The phone number is automatically stored without
pressing DONE if all 26 places are used.
To delete Downloader Phone Number, press:
Delete—Option #—06—DONE.
Option 07: Account Number (Default = 00000)
Lets you program up to a 10-character alphanumeric account
number (on) or delete an existing account number (off).
To enter letters (A - F only), press 9 then the Minutes + button.
The panel announces the letter A. Continue pressing the Min-
utes + button to progress through the alphabet.
Note
The CID format only supports account numbers with let-
ters B through F, or numbers 0 through 9 (or a combina-
tion of those letters and numbers).
To set Account Number, press:
Add—Option #—07—Up to 10 characters—DONE.
Note
Pressing DONE is required if you enter fewer than 10
characters. The account number is automatically stored
without pressing DONE if 11 characters are entered, of
which only the first 10 are stored.
To delete Account Number, press:
Delete—Option #—07—DONE.
14
Beta Test 8/10/01
Option 08: Phone Lock (Default = off)
Prevents unauthorized persons from clearing panel memory to
change phone/reporting related Options 04, 05, 06, 08, 09, 12,
and 13 (on), or allows anyone to clear panel memory and
change these option settings (off).
To turn on Phone Lock, press:
Add—Option #—08—DONE.
To turn off Phone Lock, press:
Delete—Option #—08—DONE.
Option 09: Downloader Code (Default = 12345)
Lets you set a unique 5-digit code that is required for initiating
ToolBox sessions (on) or sets the code to its default (off).
The code must be 5 digits long and can range from 00000 to
99999. The Downloader Code must match the downloader
access code in the ToolBox account to perform ToolBox ses-
sions.
Note
The downloader code should always be changed from
the default setting to avoid competitor theft.
To set Downloader Code, press:
Add—Option #—09—5-digit code—DONE.
To delete Downloader Code (return to default), press:
Delete—Option #—09—DONE.
Option 10: Entry Delay (Default = 030 sec)
Determines how long Entry Delay beeps sound to alert the user
to disarm the system when entering the armed premises
through a designated entry/exit door, before an alarm occurs.
When turned on, the Entry Delay can be set from 005-254 sec-
onds (030-254 if SIA Limits Option 69 is on). All entries must
be 3 digits. When turned off, the Entry Delay is set to 005 sec-
onds (030 if Option 69: SIA Limits is on).
Note
For UL listed systems, the entry delay must not exceed
45 seconds.
To set Entry Delay, press:
Add—Option #—10—3-digit delay time—DONE.
To reset Entry Delay (return to default), press:
Delete—Option #—10—DONE.
Option 11: Exit Delay (Default = 060 sec)
Determines how long Exit Delay beeps sound after arming the
system to alert the user to leave the armed premises through a
designated entry/exit door, before an alarm occurs.
When turned on, the Exit Delay can be set from 005-254 sec-
onds (045-254 if SIA Limits Option 69 is on). All entries must

Advertisement