Preparing for Operation
n63
UP/DOWN Command Frequency Memory
Setting range
•This constant is enabled when the Multi-function Input Selection 3 (n08) is set to UP/
DOWN command function (15).
•This constant can save the frequency command adjusted by the UP/DOWN command
in its memory. (The Inverter starts rotation at the previously-set frequency when an op-
eration input is given after restarting the power supply.)
Value
0
Memorizes the frequency
1
Does not memorize the frequency
•For clearing the memorized frequency, either set the constant to "0" or initialize again.
When re-adjusting, directly input the UP/DOWN command.
Note This constant is available for models with a PROM number (n69) of "220" or
higher.
n64
Operator's Frequency Setting Method
Setting range
•Used for setting the frequency from the Digital Operator.
•Select the Enter Key operation when setting the frequency command from the Digital
Operator.
Value
0
Enter Key required for changing frequency
1
Enter Key not required for changing frequency (may be changed using
Increment and Decrement Keys.)
Note This constant is available for models with a PROM number (n69) of "220" or
higher.
0, 1
0, 1
Factory setting 0
Description
Factory setting 0
Description
Chapter 4
4-37