Download Print this page

Omron SYSDRIVE 3G3EV User Manual page 74

Compact low-noise inverter
Hide thumbs Also See for SYSDRIVE 3G3EV:

Advertisement

Preparing for Operation
n49
S-shape Acceleration and Deceleration Characteristic
Setting range
This constant is used for the s-shape acceleration and deceleration of the Inverter to
decrease the shock of the machine connected to the Inverter when the machine starts
or stops operating.
Value
0
No s-shape acceleration or deceleration
1
S-shape characteristic time set to 0.2 second
2
S-shape characteristic time set to 0.5 second
3
S-shape characteristic time set to 1.0 second
Note If this constant is set to 1, 2, or 3, the acceleration or deceleration time will in-
crease by 0.2, 0.5, or 1.0 second respectively.
Output frequency
n50
Over-torque Detection Function Selection
Setting range
n51
Over-torque Detection Level
Setting range
Unit of setting 1 (%)
4-32
0 to 3
No s-shape acceleration or deceleration
S
S
0 to 4
30 to 200 (%)
Factory setting 0 (No S-shape
Description
S: S-shape characteristic time
Time
Factory setting 0
Factory setting 160 (%)
Chapter 4
acceleration or
deceleration)

Advertisement

loading