Download Print this page

Omron SYSDRIVE 3G3EV User Manual page 53

Compact low-noise inverter
Hide thumbs Also See for SYSDRIVE 3G3EV:

Advertisement

Preparing for Operation
Constant
Dedicated
no.
indicator
n30
n31
n32
n33
n34
n35
n36
n37
n38
n39
n40
n41
n42
n43
n44
n45
n46
n47
n48
n49
n50
n51
n52
n53
n54
n55
n56
Description
Minimum output frequency
voltage
Electronic thermal reference
current
Electronic thermal protec-
tion
Stall prevention during de-
celeration
Stall prevention level during
acceleration
Stall prevention level during
operation
Operation after recovery
from instantaneous power
interruption
Carrier frequency
Automatic torque boost gain 0.0 to 3.0
Frequency reference gain
Frequency reference bias
Frequency reference upper
limit
Frequency reference lower
limit
Frequency reference input
terminal
Multi-function analog output 0, 1
Multi-function analog output
gain
DC control current
Interruption DC control time 0.0 to 5.0
Startup DC control time
S-shape acceleration and
deceleration characteristic
Over-torque detection
Over-torque detection level
Over-torque detection time
Frequency detection level
Slip compensation gain
Motor current with no load
Jump frequency 1
Setting range
1 to 50
(see note 1)
0.0 to see note 2
0 to 4
0, 1
30 to 200
30 to 200
0, 1, 2
1, 2, 3, 4
(see note 3)
0.10 to 2.55
–99 to 99
0 to 110
0 to 110
0, 1
0.00 to 2.00
0 to 100
0.0 to 5.0
0 to 3
0 to 4
30 to 200
0.1 to 10.0
0.0 to 400
0.0 to 9.9
0 to 99
0.0 to 400
Chapter 4
Factory setting
12 (V)
(see note 1)
See note 2
0
0
170 (%)
160 (%)
0
4 (see note 4)
1.0
1.00 (times)
0 (%)
100 (%)
0 (%)
0
0
0.30
50 (%)
0.5 (seconds)
0.0 (seconds)
0
0
160 (%)
0.1 (seconds)
0.0 (Hz)
0.0 (%)
40 (%)
0.0 (Hz)
4-11

Advertisement