Download Print this page

Omron SYSDRIVE 3G3EV User Manual page 115

Compact low-noise inverter
Hide thumbs Also See for SYSDRIVE 3G3EV:

Advertisement

Appendix A
Constant
Indi-
no.
cators
n07
n08
n09
n10
n11
n12
n13
Description
9: External base block command (base
10: External base block command (base
11: Search command from maximum
12: Search command from preset
13: Acceleration/Deceleration-inhibit
14: Local/Remote changeover
Multi-function
1 to 14: Same as for n06
input selection 2
Invalid when n08 = 15
Multi-function
1 to 14: Same as for n06
input selection 3 15: Up/Down command
0: Fault occurrence
Multi-function
output selection
1: Operation in progress
1 (MA, MB)
2: Frequency matching
3: Idling
4: Frequency detection
Output frequency ≥ frequency detection
level determined with constant set in n53
5: Frequency detection
Output frequency ≤ frequency detection
level determined with constant set in n53
6: Over-torque being monitored
7: Base block in progress
8: Undervoltage (UV) being monitored
9: Speed search
10: Run mode
Multi-function
0 to 10: Same as for n09
input selection 2
(PA)
Frequency
0.0 to 400 (Hz)
reference 1
Frequency
0.0 to 400 (Hz)
reference 2
Frequency
0.0 to 400 (Hz)
reference 3
Setting range
block when ON)
block when OFF)
frequency
frequency
command
command
Chapter 7
Setting
[2]
[4]
[0]
[6.0]
[0.0]
[0.0]
7-11

Advertisement