Specifications
H Operation Specifications
Control input
Control output
Analog output
6-6
Three photocoupler input terminals (24 VDC, 8 mA)
• Forward/stop [SF]
• Reverse/stop [SR]
• Multi-function input [S1] (set in constant No. 06)
• Multi-function input [S2] (set in constant No. 07)
• Multi-function input [S3] (set in constant No. 08)
Note When 3-wire sequence mode (constant No. 01 = "9") is se-
lected, the terminals become as follows:
• Run command [SF]
• Stop command [SR]
• Forward/reverse rotation command [S1]
One analog input terminal (0 to 10 VDC or 4 to 20 mA)
• Frequency reference input [Between FC and FR]
One SPDT relay contact output terminal [MA, MB]
(30 VDC and 1A; 250 VAC and 1A)
• Multi-function contact output (set in constant No. 09)
One photocoupler input terminal [PA] (48 VDC, 50 mA)
• Multi-function photocoupler output (set in constant No. 10)
One analog voltage output [AM] (0 to 10 VDC, 2 mA)
• Multi-functional analog output (Constant No. 44 is used to set
the function and constant No. 45 is used to set the multiplying
factor.)
The output frequency or output current can be monitored. The
Inverter is factory-set to output frequency monitoring.