2.2.6

Wind averaging time

Set the wind averaging time in minutes. Select [No Averaging] for no averaging. The
higher the time, the smoother the wind data, but response to the changes in wind
speed and angle slows.
1. Press the MENU/ESC key to open the menu.
2. Select [Wind Average] then press the ENT key.
3. Select a value then press the ENT key.
4. Press the DISP key to close the menu.
2.2.7

ROT sensor

Select the ROT sensor as follows:
1. Press the MENU/ESC key to open the menu.
2. Select [ROT Sensor] then press the ENT key.
3. Select a source then press the ENT key.
[Internal]: Select this item if a rate-of-turn-gyro DS-670 (supplied locally) is con-
nected.
[External ROT]: Receive ROT data from external sensor.
[External HDG]: Calculate ROT data based on the HDG data received from exter-
nal sensor.
4. Press the DISP key to close the menu.