5. OTHER OPERATIONS
System parameters menu description
Item
Ship's Speed
Set averaging time for ship's speed. The default
Average
setting is acceptable for most conditions. If the speed indi-
cation is unstable, select the setting that gives stable speed
data.
Current Aver-
Set averaging time for current (tide) speed and direction.
age
The default setting is acceptable for most conditions. If the
current data changes randomly, select the setting that
gives stable current data, but does not slow response to
changes in current data.
Track Depth
Set the water tracking depth for measurement of through-
the-water-speed. If the through-the-water speed readout is
unstable, raise the setting.
Current Mea-
Set the depth at which to measure current (tide) speed and
surement
direction.
CALC Average
Smooth the heading data, which is received every second. No Averaging, 10s,
IR
Turn the interference rejector on or off. Turn the rejector on
when an echo sounder is connected to the DS-60, to pre-
vent mutual interference.
Log Pulse
Select the data to use to calculate distance run.
Speed
Log Pulse Out-
Select the log pulse speed to output to external equipment.
put
• Forward: Forward speed only
• Forward-After: Forward and after speeds
• Vector: Synthesized speed consisting of forward, after,
port and starboard speeds
Analog Speed
Select the source for the analog speed indication.
Analog Output
Select the analog speed to output to external equipment.
• Forward: Forward speed only
• Forward-After: Forward and after speeds
• Vector: Synthesized speed consisting of forward, after,
port and starboard speeds
Beam Direction Select the beam directions to use to measure speed. For-
ward: 0°, 120°, 240° After: 60°, 180°, 300°
TVG Curve
Used for internal calculations, and the default setting is ze-
ro. Do not change the setting. Contact a FURUNO agent or
dealer for information.
ECHO FAIL
Set the gain threshold for [ECHO FAIL] judgement. (For the
Limit
serviceman.)
5-10
Description
Available settings
5s, 10s, 15s, 30s,
60s
1min, 2min, 3min,
5min, 10min
0.5 - 25.0(m), 0.1m
steps
0.5 - 25.0(m), 0.1m
steps
30s, 60s, 90s, 120s
ON, OFF
STW&GPS;
SOG&STW&GPS;
SOG&GPS; STW
Forward; Forward-
After; Vector
STW&GPS;
SOG&STW&GPS;
SOG&GPS; STW
Forward; Forward-
After; Vector
Forward, After
0 -19
0 - 9