Furuno CSH-23 Installation Manual
Furuno CSH-23 Installation Manual

Furuno CSH-23 Installation Manual

Color scanning sonar
Hide thumbs Also See for CSH-23:

Advertisement

Quick Links

Back
COLOR SCANNING SONAR
CSH-23/23F/24/24F
MODEL

Advertisement

Table of Contents
loading

Summary of Contents for Furuno CSH-23

  • Page 1 Back COLOR SCANNING SONAR CSH-23/23F/24/24F MODEL...
  • Page 2 Printed in Japan All rights reserved. All rights reserved. Pub. No. IME-13040-J3 Pub. No. IME-13040-J3 ( ( TATA TATA ) ) CSH-23/24/F CSH-23/24/F The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer FURUNO Authorized Distributor/Dealer FIRST EDITION : FIRST EDITION :NOV.
  • Page 3 The installer of the equipment is solely responsible for the proper installation of the equipment. FURUNO will assume no responsibility for any damage associated with improper installation. WARNING Install the specified transducer tank in accordance with the installation instructions.
  • Page 4: Table Of Contents

    4.6 Connection of Interface Unit CS-120A ...24 4.7 Connection of Sub-display Unit CSH-236/236F (Option) ...29 4.8 Synchronizing Transmission with Other Sonars, Echo Sounders...30 4.9 Interlocking Operation with Other Sonar ...32 CHANGING POWER SPECIFICATIONS ... 34 6. ADJUSTMENT AND CHECK 6.1 Hull Unit Check...35 6.2 Heading Adjustment ...36...
  • Page 5: System Configuration

    CSH-220A (CSH-23/24) CSH- 220FII (CSH-23F/24F) FNZ JOINT BOX CS-170 HULL UNIT CSH-21080 (800 mm stroke)** CSH-21120 (1200 mm stroke) CSH-21160 (1600 mm stroke) **: CSH-23/24 only. Figure 1-1 System configuration SUB DISPLAY* CSH-236 *: CSH-23/23F only 100 VAC STEP-DOWN TRANSFORMER...
  • Page 6: Equipment Lists

    FP10-03000 FP10-01900 Spare Parts SP10-01700 SP10-03300 SP10-01800 SP10-03400 *:CSH-23/24 only Type CSH-23 CSH-23F CSH-24 CSH-24F CSH-23 Blackbox type CSH-23F Blackbox type CSH-23/24 CSH-23F/24F CSH-23/24 CSH-23F/24F stroke 800mm * stroke 1200mm stroke 1600mm CSH-23/24 CSH-23F/24F 1 set CP10-02710 6 pair cable...
  • Page 7 ROM Option Kit OP10-18 Hull Unit CSH-21081-1 CSH-21081-2 CSH-21121-1 CSH-21121-2 CSH-21161-1 CSH-21161-2 Ant slamming OP10-21 Mass Code No. (kg) CSH-23/23F only 006-027-830 For CSH-23/23F 000-690-855 For CSH-24/24F 006-997-710 For CSH-23/23F 000-690-856 For CSH-24/24F 000-068-165 For CSH-23/23F 000-069-996 For CSH-24/24F 000-101-006...
  • Page 8: Mounting The Equipment

    • The space shown in the figure on the next page is required around the hull unit for wiring and maintenance. • If the ambient temperature of the unit is below 0 C, provide the sonar compartment with a heater to keep the temperature above 0 C.
  • Page 9 Figure 3-2 Maintenance space, example sonar compartment...
  • Page 10 Shortening the retraction tank The retraction tank is 1300 mm in length when supplied. Shorten the tank as necessary so that the transducer is placed well below the keel when it is lowered. The following table provides guidelines for shortening the tank. Refer also to the retraction tank installation drawing at the back of this manual.
  • Page 11 Remarks for installation of retraction tank 1. Make, if possible, the installation location a double bottom structure. 2. Install, if possible, the tank on the keel where the tank can be most firmly fixed. 3. Install the reinforcement ribs as near as possible to the top of the retraction tank, allowing space for tightening of bolts and nuts.
  • Page 12 Installing hull unit on retraction tank After welding the retraction tank and allowing sufficient time for cooling, install the hull unit as follows: 1. Clean the hull unit flange, the O-ring and O-ring groove and coat them with a slight amount of grease.
  • Page 13 Installing stays (anti-vibration measure) Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron with a size of 75 x 75 x 9 mm or more and at least two pieces should be used; one each to ship’s bow and stern directions.
  • Page 14: Mounting The Display Unit/Sub-Display Unit

    3.2 Mounting the Display Unit/Sub-display Unit The display unit/sub-display unit is designed for tabletop mounting. When selecting as mount- ing location consider the following conditions: • Place where operating personnel are able to control the unit easily while observing the fish- ing ground or the area surrounding the vessel.
  • Page 15: Mounting The Transmitter Unit

    3.3 Mounting the Transmitter Unit The transmitter unit can be mounted with or without mounting legs. For use without mounting legs remove them and use inside mounting holes. The transmitter unit should be reinforced against vibration by stays extending from the eyebolts on the top of the unit.
  • Page 16: Grounding The Equipment

    3.6 Grounding the Equipment Ground all equipment with a suitable copper strap or ground wire. The location of the ground terminal of each unit is shown below. DISPLAY UNIT INTERFACE UNIT Figure 3-12 Location of ground terminals on equipment CAUTION Ground the equipment to prevent electrical shock and mutual interference.
  • Page 17: Wiring

    4. WIRING 4.1 Cable Configuration Figure 4-1 Cable configuration...
  • Page 18: How To Use The Crimping Tool, Pin Extractor

    4.2 How to Use the Crimping Tool, Pin Extractor A special crimping tool is necessary for connection of wires to the contact pins of the 38P connector. The pin extractor removes the contact pin from the connector body. This paragraph describes how to crimp and extract the contact pin.
  • Page 19: Location Of Connectors

    4.3 Location of Connectors...
  • Page 20: Fabricating Cables, Assembling Connectors

    4.4 Fabricating Cable, Assembling Connectors Fabricating cable 00-8016-038-313-761HV (CN-A1, CN-A5 and J201) Shield Vinyl sheath Core Figure 4-4 Fabrication cable 00-8016-038-313-761HV Assembling the 38P connector Shorten the unused wires appropriately and their ends with vinyl tape to prevent short circuit. Insulate unused wires with vinyl tape.
  • Page 21 Clamping the cable Clamp the cable where the shield is folded back onto the armor. Assembling connector NSC-253P (CN-A15) Figure 4-7 Assembling connector NSC-253P Assembling BNC connector (CN-A7, CN-A8, CN-A9, CN-A10, CN-A11 and CN-A12) 1. Remove vinyl sheath of the cable by 15 mm. 2.
  • Page 22 Fabricating cable 54-038-000-601/SC (CN-E1) Figure 4-9 Fabricating cable 54-038-000-601/SC Assembling 38P connector 1. Bundle the unused wires outside the connector case. 2. Fix the cover 1, taking heed of the cable outgoing direction. 3. Dress the wires and fix the cover 2 and 3. Use a fragment of cable sheath to secure the wires at the connector clamp.
  • Page 23 Positioning guide pins Guide pins of the connector are used to identify the mating receptacle. Position them shown below. Table 4-2 Guide pins and connector CN-E1 Clamping the cable (side at power supply unit) Clamp the cable as shown in below. Fabricating cable 10S1259 (connected terminal board TB-E1) Figure 4-12 Fabricating cable 10S1259 Fabricating cable DPYCY-4...
  • Page 24 Fabricating cable 54-038-000-601/SC (CN-B2, CN-B3, CN-B4) Figure 4-14 Fabricating cable 54-038-000-601/SC Assembling 38P connector 1. Bundle the unused wires outside the connector case. 2. Fix the cover 1, taking heed of the cable outgoing direction. 3. Dress the wires and fix the cover 2 and 3. Use a fragment of cable sheath to secure the wires at the connector clamp.
  • Page 25 Clamping the cable Secure the cable with the cable clamp. Figure 4-16 Clamping the cable Fabricating cable 10S1259 (connected to terminal board TB-B1) Figure 4-17 Fabricating cable 10S1259 Fabricating cable 54-038-000-601/SC (CN-C2, CN-C3 and CN-C5), 00-8016-020-313-703V (CN-C4) Figure 4-18 Fabricating cable 54-038-000-601/SC, 00-8016-020-000-703V...
  • Page 26 Assembling 38P connector 1. Bundle the unused wires outside the connector case. 2. Fix the cover 1, taking heed of the cable outgoing direction. 3. Dress the wires and fix the cover 2 and 3. Use a fragment of cable sheath to secure the wires at the connector clamp.
  • Page 27 Fabricating cable connected to terminal board TB-D1 in Raise/ Lower Control Box Figure 4-21 Fabricating cable connected to terminal board TB-D1 in Raise/Lower Control Box Fabricating cable 10S1259 (connected to terminal board TB-D2 in Raise/Lower Control Box) Figure 4-22 Fabricating cable 10S1259...
  • Page 28: Connection Of Transducer Cables

    4.5 Connection of Transducer Cables The transducer cables are supplied with connectors. Plug them into the receptacles in the re- ceiver unit, referring to the stickers on the cables. Lead the cable into the receiver unit and clamp it as follows. Ground the cable by cable clamp.
  • Page 29: Connection Of Interface Unit Cs-120A

    4.6 Connection of Interface Unit CS-120A With connection of navigator, the Interface Unit CS-120A and electronic fishing equipment, the function of the CSH-23/24 series is expanded to include true motion presentation, target lock, echo sounder picture, FNZ marker presentation and digital indication of position, water temperature and depth.
  • Page 30 There are six combinations of CIF/NMEA data input. Combination NMEA port J208 NMEA data NMEA data - NMEA data - - Note: NMEA port and CIF port are not fed a data at the same time. Either CIF current data or NMEA data can be fed to CI/NMEA port.
  • Page 31 Connections for ES picture and FNZ markers To provide echo sounder picture and FNZ markers, connect echo sounder to J203 and net sonde to J202. The signals applied to J202 and J203 are J202: Net sonde signal and trigger signal (keying pulse of echo sounder). A white line signal from an echo sounder may be additionally applied as described on the next page if the digital depth data is not available on J204.
  • Page 32 Connections for digital indication of position, water temperature and depth The data for these readouts are taken from the equipment shown in the table below and input to J208 or J204. Input to J208 if the data is NMEA format, or to J204 if the data is CIF format.
  • Page 33 Fabrication, assembling 10P and 7P connectors VINYL SHEATH VINYL SHEATH (OUTER) (INNER) SOLDER UNUSED CORES AND EARTH TO BRAIDED SHIELD WIND SHIELDING TAPE SOLDERING VINYL SHEATH ARMOR (OUTER) WIND VINYL TAPE VINYL SHEATH SOLDER UNUSED CORES AND EARTH WIRE TO BRAIDED SHIELD VINYL SHEATH WIND VINYL TAPE...
  • Page 34: Connection Of Sub-Display Unit Csh-236/236F (Option)

    The Sub-Display Unit CSH-236/236F is the same as the Display Unit CSH-230/230F in terms of outline dimension and control panel layout. It controls the sonar at a place remote from the display unit while observing picture on the screen. One sub-display unit can be connected to three display units.
  • Page 35: Synchronizing Transmission With Other Sonars, Echo Sounders

    4.8 Synchronizing Transmission with Other Sonars, Echo Sounders To synchronize the transmission of the CSH-23/24 series sonars to that of other sonars or echo sounders, wire units as follows. Connections Figure 4-33 Connections for synchronizing transmission with echo sounder having current driven KP, voltage driven KP...
  • Page 36 Note: To output KP to other sonar or echo sounder, wire units as follows. Figure 4-34 Connections for outputting KP to other sonar or echo sounder Menu setting Set polarity of the KP on the INIT SET/TEST menu. Set transmission cycle to 0 on data...
  • Page 37: Interlocking Operation With Other Sonar

    Functions (range, tilt, fish mark, etc.) and remote control may be mutually interlocked with those on other sonars (CSH-23/24/73/83/84). For example, if the range is interlocked, changing the range in one sonar automatically sets the other sonar to the same range. The functions to be interlocked can be selected on the SYSTEM menu.
  • Page 38 Connections for interlocking remote control To control multiple display units by one remote control box, wire units as follows. Connect same pin numbers. Connect same pin numbers. NH-10P NH-10P CN-A13 CN-A14 CN-A13 CN-A14 CN-A13 CN-A14 REMOTE CONTROL CONE Board CONE Board CONE Board DISPLAY 3 DISPLAY 2...
  • Page 39: Changing Power Specifications

    5. CHANGING POWER SPECIFICATIONS The display unit is set at the factory for connection to a ship’s mains of 110 VAC or 220 VAC. To power it by 100 VAC or 220 VAC, use step-down transformer PT-400, change the trans- former taps on the power supply unit as below and connect the ship’s mains directly.
  • Page 40: Adjustment And Check

    6. ADJUSTMENT AND CHECK 6.1 Hull Unit Check 1. Press the ON switch to turn on the equipment. Con- firm that the lamps above the ON and c switches light. 2. Confirm that the 5V and UP lamps on the raise/ lower control box are lit.
  • Page 41: Heading Adjustment

    12. Press the c switch. Confirm that the lamp above the switch blinks while the transducer is being raised, a short beep sounds when the mid limit switch kicks, and the lamp lights when the transducer is fully raised. 13. Press the OFF switch. Confirm that the transducer is completely retracted and then the power is turned off.
  • Page 42: Dip Switch Setting In The Display Unit

    For factory use. Set to ON always. PND Board (10switchP6714) Item SW No. Display unit setting Correction Setting Set to 30° Set to 330° Setting CSH-53 CSH-23/24 CSH-73/ (55 kHz) 83/84 Check Check Setting For 21” CRT display unit (CSH-24/24F/24FL/84) For 15” CRT display unit (CSH-23F/23FL/24F/24FL) *: Set to OFF for the Processor unit.
  • Page 43: Setting And Adjustment Of The Interface Unit Cs-120A

    6.4 Setting and Adjustment of the Interface Unit CS-120A DIP switch setting Navigation data and fishing data input from external equipment can be turned on or off by DIP switches DP-1 and DP-2 on CPU II board 10P6871 in the Interface Unit CS-120A. DP-2 CI/NMEA port Input format Input format...
  • Page 44 Depth data is selected with S5. *: Use this position for white line pulse when the depth data is taken from an echo sounder. However late model FURUNO echo sounders do not output white line pulse. Normally set to ON.
  • Page 45 10 ms after transmission to avoid false depth indication caused by unwanted noise in short ranges. Readjustment of potentiometer R27 is not required as long as CSH-23/24 series indicates the correct depth. If does not, however turn R27 to the right. Adjustment of white line output level (R55) Improper setting of potentiometer R55 causes the seabed line to be painted in deep blue due to the white line pulse.
  • Page 46 LC fixing position priority Latitude and Longitude are set to LC with S3 on the DIP switch DP-1. 1. LC-RMA from NMEA 2. LC-RMA from CI/NMEA 3. <24> from CIF port Depth priority Depth is set to CIF/NMEA with S5 on the DIP switch DP-1. 1.
  • Page 47: Processor Unit Csh-235/235F

    Horizontal, TTL level, 31.687 kHz±4 Hz, 75 Ω Vertical, TTL level, 60.111 Hz±0.0007 Hz, 75 Ω • Resolution: VGA, 640 x 481 Mount the monitor in portrait orientation. Note that FURUNO monitor model MU-151C can be used in portrait orientation. (133) 6- φ 8 Fixing holes 210 ±...
  • Page 48 Connecting cables Fabricate the cables as shown in the section “4.4 Fabricating Cable, Assembling connectors.” Connect the cables, referring to the interconnection diagrams at the back of this manual. RGB port panel Protective earth Attach protective earth cable (IV-8sq, shipyard supply) between the GND terminal of the processor unit and ship’s body.
  • Page 49 Screw (4 pcs) BNC connector Replace each BCN connector to the same label port. RGB port panel CONE board (10P6711) Processor unit (right side, cover removed)
  • Page 50: Spare Parts/Installation Materials/Accessories

    PACKING LIST CSH-235/235K/235F/535/585/735/835 N A M E ユニット UNIT 操作制御部 PROCESSOR UNIT 予備品 SPARE PARTS 予備品 SPARE PARTS 工事材料 INSTALLATION MATERIALS 工事材料 INSTALLATION MATERIALS 1.コ-ド番号末尾の[**]は、選択品の代表型式/コードを表します。 CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) DESCRIPTION/CODE №...
  • Page 51 SHIP NO. SPARE PARTS LIST FOR ITEM NAME OF OUTLINE PART ヒューズ FUSE MFR'S NAME FURUNO ELECTRIC CO.,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 006-030-590 CODE NO. SP10-03201 TYPE U S E QUANTITY DWG. NO. WORKING TYPE NO. SPARE FGBO-A 5A...
  • Page 52 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME +トラスタッピンネジ 1種 SELF-TAPPING SCREW コネクタ(NCS) CONNECTOR(NCS) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 006-030-600 CODE NO. TYPE CP10-06301 略  図 型名/規格 OUTLINE DESCRIPTIONS 6X20 SUS304 CODE NO. 000-802-084 NCS-253-P CODE NO. 000-506-503 FURUNO ELECTRIC CO .,LTD. 10CJ-X-9401 数量 用途/備考 Q'TY REMARKS 10CJ-X-9401...
  • Page 55 OUTLINE PART 管入りヒューズ FUSE XHコネクタ組品 XH CONNECTOR ASSY, コネクタ抜き工具 CONNECTOR PULLER ヒューズ FUSE MFR'S NAME FURUNO ELECTRIC CO.,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 000-070-208 CODE NO. SP10-03300 TYPE U S E QUANTITY DWG. NO. WORKING SPARE TYPE NO. 指示装置用...
  • Page 56 OUTLINE PART 管入りヒューズ FUSE XHコネクタ組品 XH CONNECTOR ASSY, コネクタ抜き工具 CONNECTOR PULLER ヒューズ FUSE MFR'S NAME FURUNO ELECTRIC CO.,LTD. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 000-070-209 CODE NO. SP10-03400 TYPE U S E QUANTITY DWG. NO. WORKING SPARE TYPE NO. 指示装置用...
  • Page 57 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME アース線組品 GROUNDING WIRE コネクタ(8016) CONNECTOR(8016) 貼りマーク.J201. STICKER.J201. コネクタ(54) CONNECTOR(54) コンタクト ピン(8017) CONTACT PIN (8017) コネクタ(RM) CONNECTOR(RM) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(8016) CONNECTOR(8016) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 58 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME クーラーパテ COOLER PUTTY イラックスチューブ(A) INSULATION TUBE(A) コネクタ(NCS) CONNECTOR コネクタ(NCS) CONNECTOR(NCS) アース板 COPPER STRAP コネクタ(8016) CONNECTOR P貼りマーク.11. P STICKER.11. コネクタ(54) CONNECTOR(54) コンタクト ピン(8017) CONTACT PIN (8017) アイボルト EYE-BOLT 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 59 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME ミガキ平座金 FLAT WASHER アース板 COPPER STRAP シールドスリーブ SHIELD SLEEVE 圧着端子 CRIMP-ON LUG 圧着端子 CRIMP-ON LUG 圧着端子 CRIMP-ON LUG 貼りマーク STICKER コネクタ(54) CONNECTOR(54) コンタクト ピン(8017) CONTACT PIN (8017) 圧着端子 CRIMP-ON LUG 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 60 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME 圧着端子 CRIMP-ON LUG ホールプラグ HOLE PLUG アース板 COPPER STRAP 貼りマーク.1. STICKER.1. コネクタ(54) CONNECTOR(54) コンタクト ピン(8017) CONTACT PIN (8017) 圧着端子 CRIMP-ON LUG 圧着端子 CRIMP-ON LUG ホールプラグ HOLE PLUG アース板 COPPER STRAP 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 61 A-12...
  • Page 62 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(8016) CONNECTOR(8016) 貼りマーク.J201. STICKER.J201. コネクタ(54) CONNECTOR(54) コンタクト ピン(8017) CONTACT PIN (8017) アース線組品 GROUNDING WIRE コネクタ(RM) CONNECTOR(RM) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(8016) CONNECTOR(8016) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 63 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME M8化粧ビス PANEL SCREW クーラーパテ COOLER PUTTY イラックスチューブ(A) INSULATION TUBE(A) コネクタ(NCS) CONNECTOR コネクタ(NCS) CONNECTOR(NCS) アース板 COPPER STRAP コネクタ(8016) CONNECTOR P貼りマーク.11. P STICKER.11. コネクタ(54) CONNECTOR(54) コンタクト ピン(8017) CONTACT PIN (8017) 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 64 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME アイボルト EYE-BOLT ミガキ平座金 FLAT WASHER アース板 COPPER STRAP シールドスリーブ SHIELD SLEEVE 圧着端子 CRIMP-ON LUG 圧着端子 CRIMP-ON LUG 圧着端子 CRIMP-ON LUG コンタクト ピン(8017) CONTACT PIN (8017) 圧着端子 CRIMP-ON LUG 圧着端子 CRIMP-ON LUG 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 65 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME ホールプラグ HOLE PLUG アース板 COPPER STRAP コネクタ(54) CONNECTOR(54) 貼りマーク STICKER 貼りマーク.1. STICKER.1. コネクタ(54) CONNECTOR(54) コンタクト ピン(8017) CONTACT PIN (8017) 圧着端子 CRIMP-ON LUG 圧着端子 CRIMP-ON LUG ホールプラグ HOLE PLUG 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 66 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME アース板 COPPER STRAP 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 006-959-800-00 CODE NO.
  • Page 67 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME 貼りマーク.J201. STICKER.J201. コンタクト ピン(8017) CONTACT PIN (8017) コネクタ(RM) CONNECTOR(RM) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(SRCN) CONNECTOR(SRCN) コネクタ(8016) CONNECTOR(8016) コネクタ(54) CONNECTOR(54) アース線組品 GROUNDING WIRE P貼りマーク.11. P STICKER.11. 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 68 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME コンタクト ピン(8017) CONTACT PIN (8017) アイボルト EYE-BOLT ミガキ平座金 FLAT WASHER アース板 COPPER STRAP シールドスリーブ SHIELD SLEEVE コネクタ(8016) CONNECTOR コネクタ(54) CONNECTOR(54) 圧着端子 CRIMP-ON LUG 圧着端子 CRIMP-ON LUG 圧着端子 CRIMP-ON LUG 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 69 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME 貼りマーク STICKER 圧着端子 CRIMP-ON LUG コンタクト ピン(8017) CONTACT PIN (8017) 圧着端子 CRIMP-ON LUG ホールプラグ HOLE PLUG アース板 COPPER STRAP コネクタ(54) CONNECTOR(54) 圧着端子 CRIMP-ON LUG コネクタ(54) CONNECTOR(54) 貼りマーク.1. STICKER.1. 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 70 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME コンタクト ピン(8017) CONTACT PIN (8017) 圧着端子 CRIMP-ON LUG ホールプラグ HOLE PLUG アース板 COPPER STRAP 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 71 A-22...
  • Page 72 A-23...
  • Page 73 A-24...
  • Page 74 A-25...
  • Page 75 A-26...
  • Page 76 A-27...
  • Page 77 A-28...
  • Page 78 A-29...
  • Page 83 Oct.31'03...
  • Page 87 Dec. 10, '02...
  • Page 88 D-10...
  • Page 89 D-11...
  • Page 90 D-12...
  • Page 91 D-13...
  • Page 92 D-14...
  • Page 93 D-15...
  • Page 94 D-16...
  • Page 95 OR MODIFY NCS-253P CN-A15 DPYCY-1.5 DPYCY-1.5 100VAC 1φ,50/60Hz 変圧器 DPYC-1.5 TRANSFORMER PT-400 アース銅板 COPPER STRAP W=50 TITLE T.YAMASAKI CSH-23/23F/23K 名称 T.TAKENO カラースキャニングソナー 相互結線図 T.Matsuguchi MASS NAME COLOR SCANNING SONAR C1304-C02- A INTERCONNECTION DIAGRAM 外部インターフェイス INTERFACE UNIT CS-120A -313-761HV J201 他端に同じ...
  • Page 97 110/220VAC キ 1φ50-60Hz チャ クロ ムラ ダイ クロ クロ アカ 10S1258 or キ S10-10-20(38P),φ18.6 クロ 20m MAX.: CSH-58 50m MAX.: CSH-23/23F/23K/73/83 チャ 80m MAX.: CSH-53 クロ ミド クロ SHIELD シールド CO-AX 同軸芯線 ミド チャ クロ アオ リモート箱 10S1627 アオ REMOTE チャ...

This manual is also suitable for:

Csh-23fCsh-24Csh-24f

Table of Contents