Si-86.book Page 2 Friday, June 23, 2000 10:26 AM
Functions
1. Functions
1.1
Indoor Unit and Outdoor Unit
Category
Functions
Energy Saving
Inverter (with Inverter Power Control)
Lower Limit of Outdoor Temperature for
Basic Funtion
Cooling Operation Limit : Outdoor
Temp. ˚C
Microprocessor Control
PAM Control (Pulse Amplitude
Modulation Control)
Horizontal Scroll, Oval Scroll
Compressor (DAIKIN SCROLL)
Swing Compressor (DAIKIN ROTARY)
Compressor
Rotary Compressor
Reluctance DC Motor
Dual Flaps
Power-Airflow Dual Flaps
Power-Airflow Flap 5 Step Control
Power-Airflow Diffuser
Comfortable
Airflow
Wide-Angle Louvers
Vertical Auto-Swing (Up and Down)
Horizontal Auto-Swing (Right and Left)
3-Step Airflow (H/P Only)
Auto Fan Speed
Silent-Operation Control
Double Thermostat Function
"Comfortable
Intelligent Eye
Control"
Comfort
Automatic Sensible Comfort Control
Control
Quick Warming Function
Hot-Start Function
Automatic Defrosting
Automatic Operation
Programme Dry Function
Operation
Height-Ceiling Application
Circulation
Fan Only
New Powerful Operation (Non-Inverter)
Inverter Powerful Operation (Increased
Air Volume / Increased Compressor
Rotation Speed)
Priority-Room Setting
Quiet Operation
Lifestyle
Laundry Programme Operation
Convenience
Energy-Saving Operation
Power Selection
Indoor Unit On/Off Switch
Signal Reception Indicator
Temperature Display
Power-Control Function
: Holding Functions
: No Functions
—
2
Category
Functions
Air Purifying Filter with Bacteriostatic,
Virustatic & Deodrizing Functions
Longlife Filter
10˚C 10˚C
Ultra-Longlife Filter (Option)
Photocatalytic Deodrizing Filter
Health
Health &
—
—
Photocatalytic Filter with UV Lamp
Clean
—
—
Mold Proof Air Filter
—
—
Washable Grille
Filter Cleaning Indicator
—
—
Healthy Cooling Operation
Good-Sleep Cooling Operation
72-Hour On/Off Timer
24-Hour On/Off Timer
—
—
Timer
12-Hour Timer
Night Set Mode
Just Fit Thermostatic Timer
—
—
Auto-Restart (after Power Failure)
—
—
Self-Diagnosis Digital Display
Self-Diagnosis LED Display
—
—
Worry Free
LCD Remote Controller (Option)
"Reliability &
The Remote Controller Loss Prevention
Durability"
—
—
with the Chain (Option)
Wiring Error Check
Anticorrosion Treatment of Outdoor
Hear Exchanger
Multi-Split / Split Type Compatible
—
Indoor Unit
Flexibility
—
Flexible Voltage Correspondence
—
Chargeless
5-Rooms Centralized Controller
—
(Option)
Field-Supply Timer Operation
Remote
Remote Control Adaptor (Option)
—
—
Control
(Normal Open-Pluse Contact)
Remote Control Adaptor (Normal Open
—
—
Contact)
—
DIII-NET Compatible (Adaptor)
—
—
Wireless
Remote
Controller
Wired
—
—
—
—
—
—
—
—
—
—
—
—
—
—
SIE-86
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
List of Function