9.6. Protocol Macro Data

Protocol macro data consists of the following components: Sequence, Step, Send Message,
Receive Message, and "Reception Matrix".
● When there is only one receive message format for one step (i.e., single send and receive
operation)
・ One receive message and one send message are set for the step.
Sequence No. 900
Sequence No. xxx
● When there are more than receive messages for one step (i.e., single send and receive
operation)
・ One send message and one reception matrix are set for the step.
・ Several "cases" (receive messages) are set for the reception matrix.
Sequence No. 900
Sequence No. xxx
9.6.1.
Format of This Protocol Macro Data
This protocol macro data has a structure without the reception matrix as shown below, since it
has only one receive message (SD_RDCODE) for one send message (SD_RDCODE). For
more information, refer to 9.6.6. Setting the Receive Message.
Sequence No. 900
Step No. 00
Step No. yy
xxx: 999 max., yy: 15 max.
Step No. 00
Step No. yy
yy: 15 max., zz: 14 max.
xxx: 999 max., Case No. 15 automatically set
Step No. 00
Setting Message 00
Receive Message 00
Send Message yy
Receive Message yy
Setting Message 00
Case No. 00
Case No. zz
Case No. 15
SD_RDCODE
9. Program
Reception Matrix
Receive Message
00
Receive Message:
zz
Other
RV_RDCODE