7.4.3. Checking the Trace Data
Using the trace data of the CX-Protocol, check that the correct data is sent and received.
In
the
CX-Protocol,
1
Upload Trace from the PLC
Menu.
A dialog box as shown in the
2
figure on the right appears. Click
Yes.
Check the Send Message and
3
Receive Message in the trace
data file shown in the figure on
the right.
* In the example on the right,
you can see that the controller
has sent the "Read trigger"
command and received the
barcode data shown in step 2
in 7.4.2.
select
■ Send Data
Hexadecimal: 3C 20 3E
Text String: "< >"
■ Receive Data
Hexadecimal: 34 39 31 32 33 34 35 36 37 38 39 30 34
0D 0A
Text String: "4912345678904"<CR><LF>