9.6. Protocol macro data

Protocol macro data consists of sequence, step, send/receive message, and matrix. Its
composition is described as follows.
●When there is only one receive message format for a step (send/receive once)
Set one send message and one receive message for the step
Sequence No.900
Sequence No. xxx
●When there are several types of receive message formats for a step (send/receive once)
Set the send message and matrix for the step
Set several types of cases (receive messages) for the matrix
Sequence No.900
Sequence No. xxx
9.6.1.
Composition of Protocol Macro Data
In this protocol macro data, there is only 1 type of receive message (SD_RDCODE) for the
send message (SD_RDCODE). Therefore, the following composition is used without using the
matrix. Refer to 9.6.6. Receive Message Settings for details.
Sequence No.900
Step No.00
Step No.yy
xxx: 999 max. yy: 15 max
Step No.00
Step No.yy
yy: 15 max
xxx: 999 max
Case No.15 is automatically set
Step No.00
Send message 00
Receive message 00
Send message yy
Receive message yy
Send message 00
Case No.00
zz: 14 max
Case No.zz
Case No.15
SD_RDCODE
9. Program
<Matrix>
Receive message
00
Receive message
zz
Other
RV_RDCODE
56