Configuring The Atm Uplink Port For In-Band Management - Nortel Passport 8250 Command Line Interface Manual

Nortel passport 8250 integrated access mux: user guide
Hide thumbs Also See for Passport 8250:
Table of Contents

Advertisement

52 Chapter 4 Other activities in the CLI
[<numPktsToRx>]
device receives from the remote host. If the number of packets is unspecified,
the routine waits for only one echo reply packet. If no packets are received
within 5 seconds, the Passport 8250 displays that there is no answer from the
remote host and exits the ping command.
Procedure
1
Example
The following is an example of sending a ICMP echo request packet from the
Passport 8250 device to a remote host at IP address 192.0.0.20 and asking for
the remote host to send one ICMP packet back to the Passport 8250 device.
Configuring the ATM uplink port for in-band management
The ibconfig command configures the ATM uplink port for in-band
management. The syntax of the command is:
where
[set]
241-5101-201 R2.2
is the number of ICMP packets that the Passport 8250
Test that a remote host is reachable from the Passport 8250 device:
ping <hostIP> [<numPktsToRx>]
[Edgeplex CLI]: ping 192.0.0.20 1
ibconfig [set]
configures the ATM uplink port for in-band management
Note: Entering the ibconfig command without the [set] parameter
displays the current in-band configuration parameters.

Advertisement

Table of Contents
loading

Table of Contents