Nortel Passport 8250 Command Line Interface Manual page 46

Nortel passport 8250 integrated access mux: user guide
Hide thumbs Also See for Passport 8250:
Table of Contents

Advertisement

46 Chapter 3 Provisioning ports and connections
2
Example
The following is an example of displaying the VPI number, VCI number,
board number, port number, number of time slots, cell delay variation
tolerance (cdvt), partial cell fill, maximum buffer size, CAS type, and CBR
clocking for structured connections mapped to ports 10, 11, and 12 on service
board 2.
Example
The following is an example of displaying the VPI number, VCI number,
board number, and port number for the connections mapped to all the ports
on service board 3.
241-5101-201 R2.2
Search for ports with connections:
mshow [<port#i>[,<#j>] [-detail]]
[Edgeplex CLI]: 2
[E1-2]: mshow 10,12 -detail
vpi=20 vci=50 --> card=2 port=10 channel(s)=0x0000fffe
cdvt=100 MaxBuffSz=250 PartFill=0 CAS=E1
cbrClock=SYNCHRONOUS
vpi=20 vci=51 --> card=2 port=11 channel(s)=0x0000fffe
cdvt=100 MaxBuffSz=250 PartFill=0 CAS=E1
cbrClock=SYNCHRONOUS
vpi=20 vci=52 --> card=2 port=12 channel(s)=0x0000fffe
cdvt=100 MaxBuffSz=250 PartFill=0 CAS=E1
cbrClock=SYNCHRONOUS
[Edgeplex CLI]: 3
[T1-3] : mshow
vpi=15 vci=101 --> card=3 port=1
vpi=15 vci=102 --> card=3 port=2
vpi=15 vci=103 --> card=3 port=3
vpi=15 vci=104 --> card=3 port=4
vpi=15 vci=105 --> card=3 port=5
vpi=15 vci=106 --> card=3 port=6
vpi=15 vci=107 --> card=3 port=7
vpi=15 vci=108 --> card=3 port=8
vpi=15 vci=109 --> card=3 port=9
vpi=15 vci=110 --> card=3 port=10

Advertisement