Nortel Passport 8250 Command Line Interface Manual page 44

Nortel passport 8250 integrated access mux: user guide
Hide thumbs Also See for Passport 8250:
Table of Contents

Advertisement

44 Chapter 3 Provisioning ports and connections
Example
The following is an example of creating an E1 CAS connection for a single
port. Time slots 1, 2, and 3 are assigned to the connection. VPI 18 and VCI
900 are assigned to the connection. The connection is mapped to port 1 on
service board 1. The mshow command is used to verify that the connection
was created.
Example
The following is an example of creating E1 CAS connections for multiple
ports. Time slots 1 to 15 are assigned to the connections. VPI 20 and VCI 50,
51, and 52 are assigned to the connections. The connections are mapped to
ports 10, 11, and 12 on service board 2. The mshow command is used to
verify that the connections were created.
Example
The following is an example of creating a DS-1 CAS connection with
extended super frame (ESF) for a single port. All 24 time slots are assigned
to the connection. VPI 200 and VCI 30 are assigned to the connection. The
connection is mapped to port 6 on service board 2. The mshow command is
used to verify that the connection was created.
241-5101-201 R2.2
[Edgeplex CLI]: 1
[E1-1]: map 1 0x0000000E 18 900 CAS=E1
[E1-1]: mshow 1
vpi=18 vci=900 ->card=1 port=1 channel(s)=0x000000000e
[Edgeplex CLI]: 2
[E1-2]: map 10,12 0x0000FFFE 20 50 CAS=E1
[E1-2]: mshow 10,12
vpi=20 vci=50 -> card=2 port=10 channel(s)=0x0000fffe
vpi=20 vci=51 -> card=2 port=11 channel(s)=0x0000fffe
vpi=20 vci=52 -> card=2 port=12 channel(s)=0x0000fffe
[Edgeplex CLI]: 2
[T1-2]: map 6 0xFFFFFF 200 30 CAS=DS1_ESF
[T1-2]: mshow 6
vpi=200 vci=30 --> card=2 port=6 channel(s)=0x00ffffff

Advertisement

Table of Contents
loading

Table of Contents