Determine the access method

Select the access method, single-number or direct meeting access, the
system will be using. With direct access, configure 10 DN pairs. In
single-number access mode, configure only the single-access DN. In both
cases, the BUI provides instructions about what to do next.

Installing the NTCW84JA I/O Panel Filter Connector for a Large System

For Large Systems, the standard IPE module I/O filtering is provided
by the 50-pin filter connectors mounted in the I//O panel on the back of
the IPE shelf. The filter connector attaches externally to the MDF cables
and internally to the NT8D81AA backplane to the I/O panel ribbon cable
assembly. For 100BaseTX TLAN operation, the standard I/O filter connector
must be replaced with the NTCW84JA ITG Line-specific I/O filter connector
for the slot occupied by the ICB card.
CS 1000 configuration
Prior to installing any of the ICB hardware, configure the system software for
the ICB card(s) through the system TTY terminal.

Summary

The following summarizes the tasks for configuring the CS 1000:
1. LD 23 - Define the ACD DN assigned to the ICB card.
2. Define DNs using either:
3. LD 11 - Configure ICB ports as digital sets.
4. LD 23 - Configure the main DN for dual-card conferences.
Nortel Communication Server 1000/Communication Server 2100 Solution/Meridian SL-100

Nortel Integrated Conference Bridge: Service Implementation Fundamentals

Copyright © 2007, Nortel Networks
.
Note: The NTCW84JA ITG-filter connector is not required on Small
Systems or Succession 1000 systems.
CAUTION
For Large systems manufactured between 1998-1999 and shipped
in North America, IPE modules have the NT8D81BA backplane
to I/O panel ribbon cable assembly with a non-removable filter
connector. The NT8D81BA is compatible with a 10BaseT TLAN. If
a 100BaseT TLAN is required, order the NT8D81AA Backplane
to I/O panel ribbon cable assembly to replace it. Do not install
the NTCW84JA filter connector onto the existing non-removable
filter connector.
LD 23 - Define ACD DNs and assign them to the ICB card.
or
LD 10 - Define Phantom TNs and forward them to the ACD DN assigned
to the ICB card.

NN43001-558/555-4001-135 01.02 Standard

ICB Release 4 20 June 2007
CS 1000 configuration 47