Nortel Secure 4134 Installation Manual page 33

Installation hardware components
Hide thumbs Also See for Secure 4134:
Table of Contents

Advertisement

The following figure shows the 1-port DS3 Medium Module.
Figure 13
1-port DS3 Medium Module
Table 16
Cable and connectors
Port
DS3
Table 17
Module LEDs
LED
LINK/STAT
STAT
Copyright © 2007, Nortel Networks
.
Connector
Recommended
cable type
Two BNC
Two 75 ohm
connectors —
unbalanced coax
one for transmit
cables (RG-179
and one for
typical)
receive
Description
Status of interface:
Off: Not connected or the interface is out of service.
Yellow: The interface is in a loopback mode or is running diagnostics
Green: The link or channel is active and receiving a valid signal
General module status:
Off: No power available to the module
Yellow: Out of service, or failed to initiate
Green: Power on and the module is operational.
Nortel Secure Router 4134
Installation — Hardware Components
NN47263-301 01.02 Standard
10.0 7 August 2007
Interface modules for the Secure Router 4134 33
Minimum
cable length
None
Maximum
cable length
450 ft (137.16 m)

Advertisement