Inner Panel Removal And Installation; Ifc (Integrated Fireplace Control) Error Codes - Regency GFi750 Owners & Installation Manual

Table of Contents

Advertisement

Inner Panel Removal and Installation

1. Remove faceplate, glass guard, door, logs, crushed glass media,
and burner (see instructions in this manual).
2. Loosen the two screws securing the brackets that hold the side
panels.
3. Remove the two back brackets and set aside.
4. Remove the side panels by tilting the top in and lifting them out.
5. Loosen the four screws and remove the mesh.
6. Remove the back panel by tilting it forward, then lifting it up and
out.
6. To install, do steps 5 to 1 in that order.
Mesh

IFC (Integrated Fireplace Control) Error codes

The IFC (Integrated Fireplace Control) in this appliance has an LED which
can inform of any error codes as a result of the appliance not turning on.
The error codes are noted below.
NOTE: Depending on the appliance this LED may or may not be visible.
- Error codes: All error codes are displayed on a set of three LEDs located
beside the SW1 switch.
- Low battery: When backup battery is under 4V the RED LED light (lo-
cated beside the SW1 switch) will pulse steadily. A double beep will be
made by the IFC whenever a command is made when backup batteries
are below 4V.
- Flame sense problem: If the pilot flame is not detected or the flame
sense system is not satisfied the RED LED light will pulse with 2 flashes
until corrected.
- Lockout: If three trials for ignition fail the RED LED indicator will pulse
three times in intervals. To clear lockout power cycle the IFC.