Smart Thermostat (Transmitter Operation)
The Smart Thermostat function adjusts the flame height in accordance to the
difference between the set point temperature and the actual room temperatures.
As the room temperature gets closer to the set point the Smart Function will
modulate the flame down.
To activate this function, press the Thermostat Key (Fig. 1) until the word
"SMART" appears to the right of the temperature bulb graphic (Fig. 11).
To adjust the set temperature, press the Up or Down Arrow Keys until the
desired set temperature is displayed on the LCD screen of the Transmitter
(Fig. 12).
Note. When Smart Thermostat is activated, manual flame height adjustment
is disabled.
Figure 11: Smart Flame Function
Fan Speed Control
If the appliance is equipped with a hot air circulating fan, the speed of the
fan can be controlled by the Proflame system. The fan speed can be adjusted
through six (6) speeds. To activate this function use the Mode Key (fig.1) to
index to the fan control icon (Fig. 13). Use the Up/Down Arrow Keys (fig.1) to
turn on, off or adjust the fan speed (fig. 14). A single "beep"
will confirm reception of the command.
Figure 13
Figure 12
Figure 14
operating instructions
Remote Dimmer Control (Light)
The auxiliary function controls the AUX power outlet by the dimmable
light control. To activate this function use the Mode Key (fig. 1) to index
to the AUX icon (fig. 15 & 16).
The intensity of the output can be adjusted through six (6) levels. Use the
Up/Down Arrow Keys (Fig.1) adjust the output level (Fig. 16). A single
"beep" will confirm reception of the command.
Note: This function is available only with the IFC Control Module.
Figure 15
Regency GFi750 Gas Inbuilt Fireplace
Figure 16
|