Fan Removal And Installation Option 1 (Front) - Regency GFi750 Owners & Installation Manual

Table of Contents

Advertisement

Fan Removal and Installation Option 1 (Front)

To Remove Fan:
1. Unplug or disconnect the power source to the stove and shut off gas
supply.
2. Remove faceplate, glass guard, door, logs, crushed glass media, burner
and inner firebox panels (see instructions in this manual).
3. Remove 10 screws from the light housing and place it on the valve
try as shown below.
4. Remove the screw from the IFC mounting bracket and gently slide it
out.
5. Disconnect the cables coming from pressure regulator motor, ignitor
and flame sensor.
6. Disconnect the three cables from the valve.
7. Remove access panel by removing 7 screws and disconnect the gasline
from the valve.
8. Remove valve tray by removing 11 screws which hold it in place. It will
be easier to process by removing the rear panel first.
9. Disconnect the three fan connectors and lift the fan up and out.
10. Reverse the above steps to install the new fan.
• Replace any damaged gaskets when reinstalling all the components.
Regency GFi750 Gas Inbuilt Fireplace