maintenance
IFC (Integrated Fireplace Control) Error Codes
IFC (Integrated Fireplace Control) Error Codes
The IFC (Integrated Fireplace Control) in this appliance has an LED which can inform of any error codes as a result of
the appliance not turning on. The error codes are noted below.
NOTE: Depending on the appliance this may or may not be visible.
- Error codes: All error codes are displayed on a set of
three LEDs located beside the SW1 switch.
- Low battery: When backup battery is under 4V the
RED LED light (located beside the SW1 switch) will pulse
steadily. A double beep will be made by the IFC whenever
a command is made when backup batteries are below 4V.
Replace with 4 x AA alkaline batteries.
- Flame sense problem: If the pilot flame is not detected
or the flame sense system is not satisfied the RED LED light
will pulse with 2 flashes until corrected.
Possible causes of flame sense problems
- The pilot is not engulfing the flame sense
- Pilot light shrinks in size
- The flame sense wire is not connected to the IFC
module.
- Proper grounding
- Flame sense and pilot hood are clean and free of any
debris
- The flame sense has no continuity (Ohms)
- The pilot flame is fluttering and not engulfing and
moving away from the flame sense
- Lockout: If three trials for ignition fail the RED LED
indicator will pulse three times in intervals. To clear lockout,
turn the remote control hand-held to OFF position and then
back to ON position.