Corner Installation; Wall And Ceiling Clearances; Mantel Clearances; Hearth Requirements - Vermont Castings Intrepid INDVR Series Installation & Operating Manual

Direct vent gas heater
Table of Contents

Advertisement

Parallel Installation: Minimum Clearance and Flue
Centerline
18³⁄₄"
(476 mm)
4"
(102 mm)
Figure 3 - Parallel Installation, minimum back and side clearance.
Corner Installation: Minimum Clearance and Flue
Centerline
7¹⁄₂"
ST947
(190 mm)
Intrepid
Parallel installation
Max. Vent
6/07
Length
24" (610 mm)
2"
(51 mm)
Figure 4 - Corner installation, minimum corner clearance and flue
centerline.

Wall and Ceiling Clearances

St948
rear corner specs
6/07
4"
(102 mm)
Sidewall/
Trim
Figure 5 - Alcove and ceiling clearances.
St949
Wall/Ceiling clearances
7
6/07
Max. Vent
Length
C L
24" (610 mm)
2¹⁄₂"
(64 mm)
4"
(102 mm)
2" (51 mm)
9"
(230 mm)
Max. Mantel
Width
Refer to
Fig. 6
(63 mm)
Rear Wall
Combustible
Mantel or Trim
Materials
B
A (Max.)
(230 mm)
7-1/2"
(190 mm)
(152 mm)
4-1/2"
(114 mm)
(76 mm)
1-1/2"
(38 mm)
A = Depth of Mantel and/or Top Trim
B = Height from Top of Heater
Figure 6 - Mantel / top trim clearances.

Hearth Requirements:

The Intrepid Heater must be installed on rigid flooring. When
the heater is installed directly on any combustible surface
other than wood flooring, a metal or wood panel extending the
full width and depth of the unit must be used as the hearth.
There are no other hearth requirements.
2¹⁄₂"

Mantel Clearances

A
3" (75mm) Min.
9
ST382
Pinnacle
mantel clearances
6"
6/13/00 djt
3"
Noncombustible
Materials
B (Min.)
10-1/2"
(270 mm)
9"
(230 mm)
7-1/2"
(190 mm)
6"
(152 mm)
4-1/2"
(114 mm)
3"
(76 mm)
20012761