Vermont Castings Intrepid INDVRBDSB Installation & Operating Manual

Vermont Castings Intrepid INDVRBDSB Installation & Operating Manual

Direct vent gas heater
Hide thumbs Also See for Intrepid INDVRBDSB:

Advertisement

Installation & Operating Manual
Installation and Appliance Setup - Care and Operation
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Call your dealer for questions on Installation, Operation, or Service.
NOTICE: SAVE THESE INSTRUCTIONS
Intrepid
Direct Vent Gas Heater
®
Model: INDVRBDSB, INDVRCBSB,
INDVR-IFT-CB, & INDVR-IFT-BD
CERTIFIED
12761
S
B
AFETY
ARRIER
Intrepid DV Cover
6/07
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
11
Vermont Castings • Intrepid DV-IFT Owner's Manual_R20 • 11/21
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death or property damage.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use
any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
– If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
DANGER
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and must be installed.
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
3-90-30007474

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings Intrepid INDVRBDSB

  • Page 1 UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 2: Table Of Contents

    PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    This appliance may be installed in an aftermarket* manufactured Verify proper operation after servicing. (mobile) home, where not prohibited by state or local codes. * Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 4: Massachusetts Safety Information

    248 CMR 5.08(2)(a)1 through 4. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 5: Framing And Clearances

    32-1/4” (819mm) 21-3/16” (538mm) 13-11/16 (347mm) 21-3/8" 24-1/4” (543mm) (616mm) Centerline of Flue Pipe 18” (457mm) Valve Inlet 4” (102mm) 21-3/4” (553mm) 13-7/8” (352mm) Figure 2.1 - Intrepid DV dimensions. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 6: Installation Requirements

    This appliance is for use only with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 7: Hearth Requirements

    Min. Height = 69-3/4”, Min. Width = 33-3/16”, Max. Depth = 18-15/16” Figure 2.7 - Alcove Clearances Figure 2.4 - Corner installation, minimum corner clearances. St948 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474 rear corner specs 01/19...
  • Page 8: Gas Specifications

    Refer to this manual for correct installation and Horizontal Run (in feet) operational procedures. For assistance or additional Figure 2.8 - Horizontal vent termination window. information consult a qualified installer, service agency, or the gas supplier. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 9 See the maker’s instructions for recommended 1 FLUE installation procedures. RESTRICTOR 10 11 12 13 14 15 16 17 18 19 Horizontal Run (in feet) Figure 2.9 - Vertical vent termination window. Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 10 When using snow blowers, make sure snow is not directed towards vent termination area. Location of Vent Termination It is imperative the vent termination be located observing the minimum clearances as shown in this manual. 1010 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 11: Chimney Diagram

     Only permitted if veranda, porch, deck or balcony is fully open requirements. on a minimum 2 sides beneath the floor. 1111 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 12 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap. Figure 2.11 - Termination clearances. 1212 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 13: Assembly And Installation

    DuraVent collar. A gas tight seal will still be made between the inner and outer pipe sections. Use a minimum of two screws to secure the SLP pipe to the starter collar. 1313 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 14: Assembling The Stove

    Read all instructions before starting installation, then follow these instructions carefully to maximize stove performance and safety. Report damaged parts to your dealer. 1414 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 15 Items required for installation: Tools: Phillips screwdriver Hammer Saw and/or saber saw Level Measuring Tape Electric drill and bits Pliers Square Building Supplies: Framing materials Wall finishing materials Caulking Material (noncombustible) 1515 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 16 INCORRECT Figure 3.2 - Make sure the seams are not aligned to prevent unintentional disconnection. Figure 3.5 - Securing Vertical Pipe Sections Figure 3.3 - Slip Section Pilot Holes 1616 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 17 When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current ANSI Z223.1 and CAN/CGA-B149 installation codes. Figure 3.8 - Align and Disassemble Vent Sections 1717 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 18 (191 mm) in diameter. a second 90° elbow), Figure 3.12. NOTE: When using flex vent, the opening will have to NOTE: Always install vertical side wall horizontal venting be measured according to the 1/2” (13 mm) rise in 12” with a 1/4” rise for every 12” of run. (305 mm) vent run. 1818 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 19 Figure 3.14 - Use extension brackets to mount snorkel against recessed wall. Termination Cap Figure 3.13 - Horizontal Termination Cap on a Vinyl Siding Wall SLP Cap ST219 snorkel detail 12/6/99 djt 1919 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 20 • For the minimum height of the vent above the highest point of penetration through the roof, Figure 3.16. Ceiling Ceiling Support Collar Support Plate Trim Plate Figure 3.16 - Typical Vertical Venting Configuration ST933 Selkirk vertical venting 6/07 2020 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 21 Planning Your Installation Pipe Section There are two basic types of installations: • Horizontal Termination, Figures 3.17 & 3.18. • Vertical Terminations, Figure 3.19 90° Elbow Figure 3.18 2121 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 22 Attach the firestop plate to the sleeve end with ZCS103 the holes, Figure 3.22. NOTE: The zero clearance sleeve Zero Clearance Sleeve is required in combustible walls only. & Firestop 12/6/99 djt 2222 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 23 1/4” (6 mm) rise for every 1’ (305 mm) of run toward 8/07 the termination. Never allow the vent to run downward. A downward slope can trap heat and become a possible fire hazard. 2323 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 24 The arrow on the vent cap should be pointing up. Ensure proper clearances to combustible materials are maintained, Figure 3.28. 2424 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 25 Step 2. The opening should be vertical rise of the venting system and any maximum of sufficient size to meet the minimum requirements for horizontal offset limitations. clearance to combustibles, as specified. 2525 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 26 The enclosure may be framed and covered with sheet rock with standard construction materials, but required clearances to combustibles must be maintained. 2626 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 27 Continue to add Minimum Clearance pipe sections until you are above the roofline. Minimum Clearance Minimum Clearance Figure 3.38 ST991 attic insul shield 8/07 2727 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 28 It may be caused by having excessive lateral runs, too many elbow and exterior portions of the system being exposed to cold weather. 2828 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 29 4-3/4" cap to adapter (121 mm) diameter sleeve on the top side of the connector. 7/07 Use three (3) sheet metal screws to assemble these two parts. 2929 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 30 If the flashing is larger than the top of the chimney, then cut and fold flashing as needed to fit chimney, Figure 3.49. Cut & Bend Flashing Sealant - Adhesive as Needed to Fit Chimney Figure 3.49 3030 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474 ST962...
  • Page 31 Retro Connector Wall Thimble Cover Masonry Bolts (4) (Not included) Figure 3.52 ST965 wall thimble 7/07 3131 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 32 (Length as required) 4 ft. (1m) of 3 in. (76mm) Flex Liner Air Intake Section Co-Axial to Co-Linear Connector (Part 46DVA - GCL) (Included in Chimney Liner Termination Kit) Figure 3.54 3232 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 33 GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE 2. Connect the thermostat wires to the valve, Figure 3.56. TECHNICIAN. FOLLOW ALL LOCAL CODES. This completes assembly of the Intrepid stove. THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY. 3333 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 34: Log Set Installation

    Intrepid left/right logs Position log so it is angled down toward the area where 7/07 the front two logs meet. Figure 3.59 - Ribs for Logs LG497 SDDVT ember bed 6/07 3434 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 35: Thermostat Connection

    NOTE: Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing. FP1622 Light the pilot according to the directions in the Operation SIT valve w/switch section of this manual. 3535 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 36 THIS APPLIANCE SHOULD BE CONNECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN. FOLLOW ALL LOCAL CODES. THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY. 3636 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 37: Indvr-Ift Wiring Requirements

    SENSE REMOTE CONTROL TO JUNCTION BOX 110-120 VAC GROUND 3 PRONG 110VAC RF MODULE 6 PIN 6V DC BATTERY PACK SPLITTER ROCKER SWITCH Figure 3.60 - INDVR-IFT Wiring Diagram 3737 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 38: Install The Safety Barrier

    NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed. 3838 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 39: Operating Instructions

    Turn clockwise counterclockwise to decrease to increase flame height flame height Figure 4.3 - Flame adjustment knob for SIT valve. FP390 FLAME ADJUSTMENT KNOB 11/21/96 3939 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 40: Lighting And Operating Instructions (Millivolt Only)

    4. Push in gas control knob slightly and turn clockwise 2. Turn off all electric power to the stove if service is to be to “OFF". Do not force. performed. 5. Close control access panel. 4040 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 41: Troubleshooting (Millivolt Only)

    (high) causing and thermocouple. the pilot safety to drop out 2. Possible blockage of the 2. Check the vent terminal for blockage (recycling the flue gases) vent terminal 4141 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 42: Read Before Lighting

    D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water. 4242 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 43: Lighting Instructions (Ift)

    For additional information on operating your Keep burner and control compartment clean. See installation and operating instructions Hearth & Home Technologies fi replace, please 593-913K accompanying appliance. refer to www.hearthnhome.com. 4343 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 44: Operation During A Power Outage - Intellifire

    • Slide the ON/REMOTE/OFF switch to the ON position NOTICE: Some functionality will be lost when using battery backup including remote control, fan, lights, or any other auxiliary functions that require household 110-120 VAC power 4444 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 45: Detailed Component Operating Instructions Intellifireā„¢ Touch

    2. If multiple control options are installed, the IFT-ECM will respond to the last command from the wired wall switch or IFT-RC400. The wired wall switch is NOT available if a Power Vent is used. 4545 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 46 • ON/OFF Functions • Flame height adjustments • Thermostat • Cold Climate Feature • Fan Speed Please refer to the instructions included with the remote control for more detailed operating instructions. 4646 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 47: Frequently Asked Question

    90 seconds. If this failure appliance did not start. Try again period of appliance inactivity. persists, contact dealer for service. by pressing Flame On. Gas control system failure. 4747 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 48: Troubleshooting

    40 ohms. If open or shorted, replace valve. Check valve harness wire continuity, if open replace 6-pin harness. Pilot won’t light, there is no noise or Spark coil failure. Replace ECM. spark, 2 Red/2 Green Lockout. 4848 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 49 Damaged pilot assembly. Check resistance between tip of sense rod and IFT-ECM connector, should be less than 1 ohm. Replace pilot assembly if damage is detected. 4949 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 50: Burner, Pilot & Control Compartment

    In normal operation, at full rate, and after operating for about 15 to 30 minutes, the flame should be yellow. NOTE: The type of installation, vent system configuration, and wind effects may cause the flame patterns to vary. CO105d Figure 4.7 - Correct pilot and burner flame appearance. Pilot flame 6/07 djt 5050 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 51: Cleaning And Maintenance

    CAUTION Turn the pilot off before painting. Allow the heater to cool completely before painting. Figure 5.2 - Release the latches to remove the glass frame. 5151 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 52: Gasket Replacement

    Do not use your stove if the flame pattern differs from that 5.1 & 5.2. To remove the old gasket, use a razor blade shown here. Contact your Vermont Castings dealer or a to separate the glass and gasket from the frame, and qualified technician for help.
  • Page 53: Wiring Diagrams

    St124c Thermostat wiring 1/11/00 djt Optional Blower Kit Schematic Diagram ST153 rdv connections diag. MOTOR 10/99 SNAPSTAT ON/OFF RHEOSTAT Figure 6.2 - Fan circuit. ST236 FK26 wiring diagram 12/99 5353 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 54 SENSE REMOTE CONTROL TO JUNCTION BOX 110-120 VAC GROUND 3 PRONG 110VAC RF MODULE 6 PIN 6V DC BATTERY PACK SPLITTER ROCKER SWITCH Figure 6.3 - INDV-IFT Wiring Diagram 5454 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 55: Service Parts List

    INDVRCBSB (Classic Black) INDVRBMSB (Majolica Brown) (End Manufacturing Date: Mar 2019) INDVRBDSB (Bordeaux) INDVRBSSB (Biscuit) (End Manufacturing Date: Mar 2019) 24 25 23.2 23.1 Part number list on following page. 06/21 5555 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 56 Brown Majolica SRV30004920 Classic Black 1306333A Biscuit SRV30003182 Bordeaux 30006716A Brown Majolica SRV30004830 Door, Control 30003945A Hinge, Control Door 1601670 Rear Shroud Assembly 30004132 Additional service parts on following page 5656 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 57 Magnet, Door 1408818 or silicone to attach Knob Extension, Hi/Lo 43D0095A Knob Extension, On/Off 43D0094A Tie Bracket Assembly 20012514 Right Burner Support Assembly 20012909K Additional service parts on following page 5757 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 58 Biscuit SRV30003214 Majolica SRV30004831 Classic Black 1302272A Bordeaux SRV30006721 Shelf Bracket Biscuit SRV30003215 Majolica SRV30004832 Conversion Kits Conversion Kit, NG to LP LPK-INDVR-SP Conversion Kit, LP to NG 20012910 5858 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 59 Beginning Manufacturing Date: Feb 2019 Gas Stove Ending Manufacturing Date: Active Intrepid Direct Vent/Rear Vent Gas Heater w/IFT Controls INDVR-IFT-CB (Classic Black) INDVR-IFT-BD (Bordeaux) Part number list on following page. 10/19 5959 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 60 Fan Cover Shroud 30004014 2166-302 Valve Propane 2166-303 Pilot Assembly SRV4602-300 SRV593-528 Pilot Orifice Propane SRV4602-301 Orifice Hood, #49/.073 SRV4604-317 Orifice Hood, #56/.0465 30000336 Additional service parts on following page 6060 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 61 Conversion Kit Propane to NG SRV30007477 NGK-DXV-50 Regulator SRVLPK-DXV-50 Propane **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 3A fuse, 3/4” long 6161 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 62: Optional Accessories

    2. Position the shelf and adjust the brackets so the shelf RCB,RCMT TSST, RCST fits correctly. 3. Tighten the screws. Refer to the instructions included with each warming shelf for complete installation procedures. 6262 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 63: Warranty Policy

    Firebox and heat exchanger, FlexBurn® System 3 years Lifetime (engine, inner cover, access cover and fireback) None 1 Year All purchased replacement parts Page 1 of 2 4021-645L 10/20 6363 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 64 EXPRESSED WARRANTY SPECIFIED ABOVE FOR THE APPLICABLE PRODUCT. Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Page 2 of 2 4021-645L 10/20 6464 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 65 6565 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...
  • Page 66 INDVR-IFT Series 64.0 76.5 les caractéristique de rendement énergétique de foyer au gaz Énerguide Based on CSA P.4.1-09 Selon CSA P.4.1-09 352 Mountain House Road • Halifax, PA 17032 www.vermontcastings.com 6666 Vermont Castings • Intrepid DV-IFT Owner’s Manual_R20 • 11/21 3-90-30007474...

Table of Contents