WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manually.
When lighting the pilot follow these instructions exactly.
B. BEFORE LIGHTING smell all around the heater area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any fireplace
• Do not touch any electric switch
• Do not use any phone in your building
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the Fire
Department
1. STOP! Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. Turn the On/Off switch to "OFF" position, set the remote
to OFF or set thermostat to lowest level.
4. Open control access panel.
5. Push in gas control knob slightly and turn clockwise
to "OFF".
6. Remove glass door before lighting pilot. (See Glass
Frame Removal section).
SIT NOVA
7. Wait five (5) minutes to clear out any gas. Then smell
for gas, including near the floor. If you smell gas, STOP!
Follow "B" in the safety information above. If you do
FP1067
not smell gas, go to the next step.
lighting instruction
8. Visibly locate pilot by the main burner.
knobs
3/9/01 djt
9. Turn knob on gas control counterclockwise
to "PILOT".
1. Turn the On/Off switch to Off position or set the
thermostat to lowest setting.
2. Turn off all electric power to the fireplace if service
is to be performed.
32

Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING
Lighting Instructions
OFF
Honeywell
To Turn Off Gas To Heater
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, do not try to repair it, call a qualified service
technician. Applying force or any attempted repair may
result in a fire or explosion.
D. Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect
the heater and to replace any part of the control system
and any gas control which has been under water.
10. Push the control knob all the way in and hold.
Immediately light the pilot by repeatedly depressing
the
piezo spark ignitor until a flame appears. Continue to hold
the control knob in for about one (1) minute after the pilot
is lit. Release knob and it will pop back up. Pilot should
remain lit. If it goes out, repeat steps 5 through 8.
• If knob does not pop up when released, stop and
immediately call your service technician or gas supplier.
• If after several tries, the pilot will not stay lit, turn the gas
control knob to "OFF" and call your service technician
or gas supplier.
3/8" - 1/2"
11. Replace glass door.
12. Turn gas control knob to "ON" position.
13. Turn the On/Off switch to "ON" position or set thermostat
to desired setting.
14. Turn on all electrical power to the fireplace.
3. Open control access panel.
4. Push in gas control knob slightly and turn clockwise
to "OFF". Do not force.
5. Close control access panel.
FP1068
Lighting instruction
Pilots
20012761

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intrepid indvrcbsb

Table of Contents