Siemens SIMADYN D FM 458 User Manual page 79

Application module
Table of Contents

Advertisement

Configuring
For modes 0, 2, 3 and 4, sources must be assigned to initiate the
Interrupt task
configured interrupt tasks.
The settings are made in HW Config in the Properties window under the
"Interrupt task" tab, dependent on the configured hardware components.
Interrupt source to be set for interrupt task Ix of the SIMOLINK blocks, if:
Mode
EXM 448-1/ITSL,
1st expansion
0
LE bus interrupt 1
2
LE bus interrupt 5
3
LE bus interrupt 1
4
LE bus interrupt 1
Table 4-4
Interrupt task source assignment for expansion modules with SIMOLINK
Fig. 4-13
The SIMOLINK blocks @SL, SLAV, SLD, SLDIS, SLSV, SLSV2 and
Hardware
SLSVAV must be assigned to a HW address in the HW Config properties
addresses,
window of the EXM 448 under the "Plug-in module / I/O addresses tab.
SIMOLINK blocks
The "process I/O" should be activated as plug-in module type. After this,
symbolic names can be assigned for the I/O addresses (pre-set symbolic
names are entered via the "Default" button.
The SIMOLINK blocks only use the symbolic name under "I/O address 2"
(SIMOLINK does not require "I/O address 1").
4-24
EXM 448-1/ITSL,
optional SLB module
2nd expansion
ITSL, 1st expansion
LE bus interrupt 3
LE bus interrupt 2
LE bus interrupt 6
LE bus interrupt 7
LE bus interrupt 3
LE bus interrupt 2
LE bus interrupt 3
LE bus interrupt 2
Alarm task setting in the HW Config
optional SLB module
ITSL, 2nd expansion
LE bus interrupt 4
LE bus interrupt 8
LE bus interrupt 4
LE bus interrupt 4
Application Module FM 458 - User Manual