Siemens SIMADYN D FM 458 User Manual page 35

Application module
Table of Contents

Advertisement

Product description
Absolute value
encoders
Power supply
voltage for the
encoders
Voltage, currents
Power loss/
fan
Dimensions
2-24
Number
Version
Types which can be connected
Protocols
Data formats
Data direction
Uni-directional
Bi-directional
Data bits
Pulse frequency, max.
Electrical isolation
Input voltage
Version
Output voltage, typ.
Output current, max.
Rated voltages at 25° C
+5 V
Power loss, typ.
Fan required
Number of slots required
in the subrack
Dimensions W x H x D [mm]
Weight, approx.
4
Differential inputs, RS485 signal level
SSI, EnDat
Gray, binary
SSI : uni-directional
EnDat : bi-directional
SSI: 13 + parity, 25 + parity
EnDat: variable
2 MHz
No
RS485 signal level
13.5 V
150 mA (short-circuit proof, short-
current, approx. 250 mA)
Typical current drain
2.8 A
14.0 W
Yes
1
24 x 290 x 210
0.76 kg