Configuring

Fig. 4-37
4.5.4.3 Configuring
For the "Automatic mode memory card" mode, only the TAB and/or
TAB_D have to be configured depending on whether tabular values, data
type REAL and/or DINT are to be managed. Each table may only contain
values of one data type. If several tables having different data types are to
be managed, a TAB or TAB_D must be configured for each table.
The TAB and TAB_D function blocks should be configured in a sampling
time greater than or equal to 32ms. The following connection settings are
required:
4-62
Example of a file whose tabular values are separate by tabs
CTS=
0
Not assigned
US =
Name of the table file
NAM =
AUT =
1 (automatic mode activated)
Application Module FM 458 - User Manual
6DD1904-0AE0
Edition 12.2001