2.3.5 Incremental encoder settings

Switches S1 and S3 are used to change over between 15V and 5V
encoders. Tracks A/VW and B/RW have a common switch, track N/- of a
channel has its own switch, which can be used to set the appropriate
encoder type:
• Switch open (OFF): 15 V encoder: Switching threshold = 7 V
• Switch closed (ON): 5 V encoder: Switching threshold = 0 V
Switch S1 and S3
8
7
6
5
4
3
2
1
ON
OFF
Table 2-19
Application Module FM 458 - User Manual
6DD1904-0AE0
Edition 12.2001
Encoder
Channel
Track
Numbr
Encoder 1 A / VW
B / RW
N / -
Encoder 2 A / VW
B / RW
N / -
Encoder 3 A / VW
B / RW
N / -
Encoder 4 A / VW
B / RW
N / -
Encoder 5 A / VW
B / RW
N / -
Encoder 6 A / VW
B / RW
N / -
Encoder 7 A / VW
B / RW
N / -
Encoder 8 A / VW
B / RW
N / -
Switch settings for 5 V- and 15 V encoders
Product description
15 V encoders
Switch
Position
Numbr
S1, 1
OFF
S1, 1
S3, 1
OFF
S3, 1
S1, 2
OFF
S1, 2
S3, 2
OFF
S3, 2
S1, 3
OFF
S1, 3
S3, 3
OFF
S3, 3
S1, 4
OFF
S1, 4
S3, 4
OFF
S3, 4
S1, 5
OFF
S1, 5
S3, 5
OFF
S3, 5
S1, 6
OFF
S1, 6
S3, 6
OFF
S3, 6
S1, 7
OFF
S1, 7
S3, 7
OFF
S3, 7
S1, 8
OFF
S1, 8
S3, 8
OFF
S3, 8
2
5 V encoders
Switch
Position
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
2-27