Temperature / Pressure Sensor Options
Notes: Sensors cannot be used with an LMV51.040xx (no load controller)
For 0-15 PSIG applications, 0-10 VDC is recommended
Water temperature sensor is needed for temperature based cold start
7MF1564xx.. Steam pressure sensors
Pressure connection is male 1/4" NPT
1/2" NPSM conduit connection, terminal connections
PSIG
0-15
0-30
0-60
0-150
0-200
0-300
0-500
QAC22
1000 ohm 2 wire nickel RTD
Needed for ambient temperature and efficiency calculations
0.56 " opening, terminal connections
Range -20 to 125
RBF195M482-010-00-8HN31
1000 ohm 2 wire platinum RTD, with aluminum weather head
Needed for stack temperature and efficiency calculations
1/2" NPT SS connection,10" insertion x 1/4" OD probe
3/4" NPT conduit connection, terminal connections
Range -40 to 900
QAE2020.005
1000 ohm 2 wire platnium RTD (Replaces 556-541)
Needed for ambient temperature or water temperature
4" x 1/4" OD spring loaded probe, 4" long SS thermowell,
3/4" NPT conduit connection, 3" wire leads
Range -13 to 266
RBF195M483- S4C05(1/2)09- SL-6HN31
1000 ohm 3 wire platinum RTD, with aluminum weather head
Needed for water temperature
4" insertion, spring loaded probe, 1/2" NPT SS thermowell
3/4" NPT conduit connection, terminal connections
Range -40 to 900
R1T185M483- S4C05(1/2)09- SL-6HN31
100 ohm 3 wire platinum RTD, with aluminum weather head
Needed for water temperature
4" insertion, spring loaded probe, 1/2" NPT SS thermowell
3/4" NPT conduit connection, terminal connections
Range -40 to 900
LMV5 QSG Rev 4
4-20 mA
BB0
7MF15644
03EA1
BE0
7MF15644
03EA1
BF0
7MF15644
03EA1
CA0
7MF15644
03EA1
CB0
7MF15644
03EA1
CD0
7MF15644
03EA1
CE0
7MF15644
03EA1
o
F
o
F
o
F
o
F
o
F
Sec 1
0-10 VDC
BB1
7MF15644
03EA1
BE1
7MF15644
03EA1
BF1
7MF15644
03EA1
CA1
7MF15644
03EA1
CB1
7MF15644
03EA1
CD1
7MF15644
03EA1
CE1
7MF15644
03EA1