Symptom
1122 jam may occur at the paper feed dispose assembly during the finisher is operating
-1122 jam: Finisher feed sensor (S0102) stationary jam
Cause
A long time use of finisher increases the frictional resistance between the roller shaft [1] of the paper
feed dispose assembly and the bushing [2]. As a result, the number of revolutions is reduced and the
paper will not be fed in the specified speed, and this leads to the above mentioned symptom.
Service work
When the above mentioned symptom has occurred, prepare the new type roller shaft (4C5-0098-000) and
the bushing (FC5-4729-000) to replace with them following the procedure below:
pg. 132