4-7-10. Detail Level Adjustment
Equipment: Analog waveform monitor
Test Points: G/Y OUT (pin 4), G/Y GND (pin 3)
/VTR connector (camera adaptor)
Object:
Grayscale chart
Preparations
. Setting for MSU-700
DETAIL OFF button → ON (dark)
KNEE OFF button → OFF (lit)
. Connect the waveform monitor to the VTR connector of
the camera adaptor.
. Shoot the grayscale chart so that the chart frame is
aligned with the underscanned monitor frame.
. Iris of the lens: A = 600 ± 20 mV (terminated with 75 Z)
Adjustment Procedure
MSU menu operation:
. PAINT button → ON (lit)
. Touch panel operation
(Page 1/3) → [Detail] → [Detail|1]
Adjustment Item: Level
Specification:
Adjust the detail level to be added to
each step of the grayscale for the
desired level.
HDC-750A
http://getMANUAL.com
4-7-11. Crispening Adjustment
Equipment: Analog waveform monitor
Test Points: G/Y OUT (pin 4), G/Y GND (pin 3)
Object:
Note
Perform this adjustment to suit the customer's preferences
if required.
Preparations
. Setting for MSU-700
DETAIL OFF button → ON (dark)
. Connect the waveform monitor to the VTR connector of
the camera adaptor.
. Shoot the grayscale chart so that the chart frame is
aligned with the underscanned monitor frame.
. Iris of the lens: A = 600 ± 20 mV (terminated with 75 Z)
A
Adjustment Procedures
1. Adjust the white balance.
WHITE button/MSU-700 → ON (lit)
2. Adjust the crispening level.
MSU menu operation:
. PAINT button → ON (lit)
. Touch panel operation
Adjustment Item: Crispening
Specification:
/VTR connector (camera adaptor)
Grayscale chart
(Page 1/3) → [Detail] → [Detail|1]
Set Crispening to _99 once. And
turn slowly for increment until the
noise at the black level of the
waveform is just decreased, or until
an appropriate crispening level is
obtained.
4-7. Overall Video Adjustment
A
4-21 (E)

Advertisement