Extron electronics XTP II CrossPoint 1600 User Manual page 156

Configurable digital video matrix switchers
Hide thumbs Also See for XTP II CrossPoint 1600:
Table of Contents

Advertisement

5.
Connect the wires to the appropriate prongs of the power plug and assemble the plug,
as detailed in the instructions that accompanied the plug.
6.
Plug the power cord into the 220 VAC power outlet.
Replacing the cable
ATTENTION:
The replacement power cable must be no longer than 9.85 feet (3 m) and rated for
200-240 VAC, 16 amps, minimum.
La longueur du câble d'alimentation de substitution doit être inférieure ou égale à
3 mètres (9,85 pieds) ; le câble doit être évalué pour 16 ampères à 200/240 Vca
minimum.
Ensure that the replacement wiring is in accordance with the electrical code for
the country or region where installed and the wiring color code in force for the
installation site. See the wire and connector specifications in
Assurez-vous que le câblage de substitution installé soit conforme aux
réglementations en matière d'électricité du pays ou de la région, et aux codes
couleurs en vigueur dans le lieu d'installation. Consultez les spécifications du câble
et du connecteur sur la
Replace the power cable as follows:
1.
If the switcher is powered, unplug it or remove power from the power outlet or junction
box that powers the switcher.
2.
On the rear of the switcher, remove and retain the 15 screws that secure the lower
panel (the panel with the power connection) in place (see figure 78).
Figure 78.
3.
Pull the fan assembly out of the cabinet (see figure 79,
1
1
3
3
Figure 79.
XTP II CrossPoint 1600, 3200, and 6400 Switchers • Maintenance and Modifications
figure
82, page 150.
Power Panel Screw Locations
2
2
3
3
Remove Fan Assembly, Ground Stud, and Power Distribution Box
figure 82