SIS Command and Response Table for Output-Board-Specific Commands (continued)
Command Function
XTP power
ATTENTION:
Power over XTP (PoX) is intended for indoors use only. No part of a network that uses PoX can be routed outdoors.
PoX est destiné à une utilisation en intérieur uniquement. Aucune partie d'un réseau qui utilise PoX ne peut être routée en extérieur.
NOTES:
PoX is supplied by the XTP II CrossPoint 48 V power supply.
XTP II CrossPoint 1600:
Can power up to 28 total (input and output) endpoints at up to 364 watts.
Is available with optional 48 V power supply redundancy.
XTP II CrossPoint 3200:
Can power up to 24 total (input and output) endpoints at up to 312 watts.
No 48 V power supply redundancy is available.
XTP II CrossPoint 6400:
Can power up to 128 endpoints at up to 1664 watts.
48 V power supply redundancy is standard.
Enable or disable power to output
endpoint and report status
View output power status
Enable or disable output power and
report status, all outputs
View all output power status
View XTP power usage
Example:
:
NOTE
X@
= Output number
X2#
= Enable or disable for power
X2$
= Amount of power requested
X2%
= Power status
X2^
= Wattage
X2&
= Power supply status
SIS Command
Response
(Host to Unit)
(Unit to Host)
Outputs on XTP CP 4o [XTP] Boards
E
X@
X2#
}
O
*
POEC
PoecO
E
X@
}
X2#
O
POEC
E
X2#
}
O
*POEC
PoecO00*
E
}
X2#
OPOEC
E
}
X2^
TPOEC
E
}
TPOEC
450*0
01
16
,
32
, or
64
0
= Disable (default)
or
(watts)
00
13
= Unpowered endpoint
0
= Power provided to endpoint
1
Power usage in 0.1 watt increments. Example: 260 = 26.0 watts watts
0
= Ok
XTP II CrossPoint 1600, 3200, and 6400 Switchers • Programming Guide
Additional Description
X@
X2#
X2$
X2%]
Enable or disable (
*
*
*
X@
output
X2$
watts and the power status is
X2$
X2%]
*
*
X2#
X2#
X2#
]
X2#
Each
1
2
...
n
an output, starting at 1. n is 16, 32, or 64.
X2#
X2#
X2#
]
...
1
2
3
n
X2&]
Show PoX wattage applied and the
*
status of the 48 V power supply.
]
The switcher is providing 45.0 watts
and the power supply is Ok.
1
= Enable
= Power available but disabled
2
= No power available, but enabled
3
1
= Not Ok
X2#
) remote power on
. The endpoint is requesting
X2%
.
is the enable or disable status of
= Fault
4
105