Chapter 6 — Setting Up the Printer
Incrementation/Decrementation
COUNT& "INC", <counter number>,"<incr. value>|<decr. value> "
<incr. value>
<decr. value>
Default:
Stop Value
COUNT& "STOP", <counter number>,"<stop value>"
<stop value>
Default:
Restart Value
COUNT& "RESTART", <counter number>,"<restart value>"
<restart value>
Default
Note: Counters are not saved in the printer's permanent
memory, but must be transmitted to the printer after each
power-up.
6.7 Enabling/Disabling Label Taken Sensor
The printers can, as an option, be fi tted with a so called label taken
sensor (LTS) that detects if there is a label left in the printer's outfeed slot
and holds the printing until the label has been removed. This facility is
especially useful for batch printing.
You can enable or disable this function by means of the following
instruction. By default, LTS is disabled.
LTS& ON | OFF
64
Intermec Direct Protocol v7.80 Programmer's Reference Manual
sets the value by which the counter should be incremented.
sets the value by which the counter should be decremented. Decrementation
is indicated by a leading minus sign (-).
1
sets the value after which the counter should start all over again at the restart
value.
2,147,483,647 (numeric) or Z (alpha)
sets at which counter value the counter should start all over again after
having exceeded the stop value.
1 (numeric) or A (alpha)